Home > Products > By type > Blower Fans > FFB03812VHN | Delta Electronics 12VDC 10.2W Axial Fan for Server and Telecommunications Cooling

FFB03812VHN Delta Blower Fan

Brand :
Delta
Model:
FFB03812VHN | Delta Electronics 12VDC 10.2W Axial Fan for Server and Telecommunications Cooling
Type:
Blower Fans
Industry:
Data Center Cooling
Description:

FFB03812VHN puts a 23000 rpm axial fan assembly into a 38 x 38 x 28 mm space. Listed for server and telecom cooling on 12VDC, it has an 846.9 Pa maximum static-pressure specification and 10.2 W input.

Datasheet:
FFB03812VHN | Delta Electronics 12VDC 10.2W Axial Fan for Server and Telecommunications Cooling Datasheet (Pdf)

Product Features

Rated Voltage(V)12
Size(mm)38x38x28
Max.Air Flow(m³/h)38.6
Max.Pressure(Pa)846.9
Input Power(W)10.2
Speed(rpm)23000
Noise(db)62.5

Product Features

DC Equipment Cooling

The FFB03812VHN addresses ventilation needs in telecommunications equipment. Delta's brushless DC axial fan format allows cooling airflow to be integrated alongside the equipment's heat-producing assemblies.

The listed 10.2 W input is relevant to supply sizing and the system energy budget; actual consumption depends on the operating duty. Its high-performance fan family emphasizes air delivery and pressure capability, helping address the resistance of densely populated equipment. Selecting the operating point against real pressure loss helps avoid oversizing and keeps thermal design focused on useful air delivery.

Equipment manufacturers and maintenance teams should match the complete part number and installation limits for reliable operation across the service cycle.

Application Industry

Frequently Asked Questions

Can FFB03812VHN run continuously in 24/7 equipment?

The supplied filter data does not establish an unconditional 24/7 rating. Confirm bearing life, temperature range, duty cycle and derating in the exact datasheet, then validate system-level redundancy.

How should the pressure capability of FFB03812VHN be checked?

The workbook lists 846.9 Pa maximum pressure. Maximum pressure and maximum airflow occur at different points, so select FFB03812VHN from its curve at the required system resistance.

What should be checked if FFB03812VHN fails to start?

Isolate power first. Verify the approved supply, connector, polarity or phase, control-enable input and any obstruction; follow the exact specification and do not bypass protection circuits.

What equipment is FFB03812VHN intended to cool?

FFB03812VHN is listed for Server and Telecommunications cooling. Confirm the installed airflow demand, pressure loss and ambient conditions before approval.

What power figure is listed for FFB03812VHN?

10.2 W is shown in the filter data. Check whether the corresponding datasheet defines it as rated, free-air or maximum-load input before sizing the power source.