A 6 W input and 13000 rpm speed define FFB0412SHN for server and telecom ventilation. Operating on 12VDC, this axial fan measures 40 x 40 x 28 mm and lists 40.8 m3/h maximum airflow in the supplied data.

Datasheet:
FFB0412SHN | Delta Electronics 12VDC 6W Axial Fan for Server and Telecommunications Cooling Datasheet (Pdf)

Product Features

Rated Voltage(V)12
Size(mm)40*40*28
Max.Air Flow(m³/h)40.8
Input Power(W)6
Speed(rpm)13000
Noise(db)54.5

Product Features

Compact DC Cooling

Delta FFB0412SHN serves power-supply equipment as a brushless DC axial fan. Equipment builders can use its mechanical format to establish forced ventilation near heat-producing parts.

The listed 6 W input is relevant to supply sizing and the system energy budget; actual consumption depends on the operating duty. Its high-performance fan family emphasizes air delivery and pressure capability, helping address the resistance of densely populated equipment. Acoustic results depend on the enclosure and duty point; smooth inlet geometry helps control avoidable airflow noise.

For procurement, retain the complete model code and check the interface against the drawing; this supports repeatable assembly and accurate replacement ordering.

Application Industry

Frequently Asked Questions

Why choose FFB0412SHN over a general-purpose fan?

FFB0412SHN provides a defined axial fan format with a listed 13000 rpm speed in a 40 x 40 x 28 mm size. Compare its fan curve with the actual duty point rather than assuming a universal advantage.

Can FFB0412SHN run continuously in 24/7 equipment?

The supplied filter data does not establish an unconditional 24/7 rating. Confirm bearing life, temperature range, duty cycle and derating in the exact datasheet, then validate system-level redundancy.

What maximum airflow is listed for FFB0412SHN?

The workbook lists a maximum airflow of 40.8 m3/h. This is not the airflow at every system resistance; use the applicable pressure-flow curve to identify the installed operating point.

What equipment is FFB0412SHN intended to cool?

FFB0412SHN is listed for Server and Telecommunications cooling. Confirm the installed airflow demand, pressure loss and ambient conditions before approval.

What should be checked if FFB0412SHN fails to start?

Isolate power first. Verify the approved supply, connector, polarity or phase, control-enable input and any obstruction; follow the exact specification and do not bypass protection circuits.

What supply voltage should be used for FFB0412SHN?

12VDC is listed for FFB0412SHN. Verify the allowable input range, phase, frequency where applicable, polarity and wiring diagram in the exact specification.