Get Quote
Home > Products > By type > Axial Fans > EEC0384B1-0000-A99 | SUNON 48V 9.7W 120x120x38mm DC Axial Fan for Refrigeration Equipment

EEC0384B1-0000-A99 SUNON Axial Fan

Brand :
SUNON
Model:
EEC0384B1-0000-A99 | SUNON 48V 9.7W 120x120x38mm DC Axial Fan for Refrigeration Equipment
Type:
Axial Fans
Industry:
Refrigeration Equipment
Description:

Sized for telecom cabinets, base stations, and network equipment, SUNON EEC0384B1-0000-A99 is a 48 VDC DC axial fan in a 120 × 120 × 38 mm frame. Up to 234.5 m³/h is its most prominent listed performance figure. The recorded model record should guide noise-control planning. Confirm environmental protection for the ordered version.

Datasheet:
EEC0384B1-0000-A99 | SUNON 48V 9.7W 120x120x38mm DC Axial Fan for Refrigeration Equipment Datasheet (Pdf)

Product Features

Rated Voltage(V)48
Size(mm)120x120x38mm
Max.Air Flow(m³/h)234.5
Max.Pressure(Pa)89.7
Input Power(W)9.7
Speed(rpm)3100
Noise(db)48

Product Features

High Airflow Cooling

The EEC0384B1-0000-A99 from SUNON addresses cooling needs in refrigeration equipment. As a DC brushless axial fan, it creates a defined inlet-to-outlet route across the thermal load.

Its listed maximum airflow of 234.5 m3/h gives engineers a basis for estimating enclosure air exchange, with installed performance determined by the resistance of the complete system. A documented PWM input allows system demand to regulate speed, supporting part-load energy use and acoustic control.

The final EEC0384B1-0000-A99 selection should consider connector reach as part of the installation layout. Finishing wiring verification in equipment qualification helps reduce integration uncertainty and supports reliable equipment cooling. Confirm that the mating lead reaches without tension or sharp bending.

Application Industry

Frequently Asked Questions

Does EEC0384B1-0000-A99 support speed control?

Speed-control capability is not stated for this complete part number. Confirm the signal and controller requirements before use.

How can EEC0384B1-0000-A99 affect operating cost?

Compare its listed 9.7 W input with the required airflow and run time. Total savings depend on the complete system duty point.

What noise data are available for EEC0384B1-0000-A99?

The worksheet lists 48 dB. Installation distance, airflow resistance, and enclosure acoustics can change the measured result.

What should be checked if EEC0384B1-0000-A99 stops?

Verify supply, wiring, obstructions, impeller movement, and protection status. Use the model datasheet before replacement or repair.

Does EEC0384B1-0000-A99 have a documented pressure rating?

Yes. The worksheet lists up to 89.7 Pa; compare it with the system curve.

Message Form