Within servers and data-center electronics, SUNON XG80564BX-1Q010-S9W serves as a 80 × 80 × 56 mm DC blower operating at 51 VDC. The supplied data list 87.2 dB, an important acoustic selection parameter. Review its equipment fit during technical purchasing. Request the exact performance curve for final engineering signoff.
| Rated Voltage(V) | 51 |
|---|---|
| Size(mm) | 80x80x56 |
| Max.Air Flow(m³/h) | 169.6 |
| Max.Pressure(Pa) | 9.49 |
| Input Power(W) | 102 |
| Speed(rpm) | 18500/16000 |
| Noise(db) | 87.2 |
For industrial equipment, SUNON XG80564BX-1Q010-S9W serves as a DC brushless axial fan. The fan supports temperature control in equipment that runs through sustained or repeated duty cycles.
The SUNON product series carries RoHS compliance and recognized safety approvals; buyers should confirm the approval marks for this exact suffix and target market. Correct airflow direction and inlet clearance help translate the documented operating point into reliable equipment-level cooling.
Design approval for XG80564BX-1Q010-S9W should cover cable routing together with prototype trials for service documentation. This creates a practical link between thermal validation, purchasing documentation and future servicing. Use a representative assembly rather than an unrestricted bench setup.
It is listed for servers and data-center electronics. Check dimensions, airflow, pressure, and the installation environment against the actual equipment.
The exact IP or protection option is not stated in the supplied row. Confirm the full suffix in the applicable SUNON datasheet.
Match voltage, dimensions, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.
Stock and lead time can change. Confirm the exact suffix, quantity, and delivery date with the supplier before ordering.
The worksheet lists 87.2 dB. Installation distance, airflow resistance, and enclosure acoustics can change the measured result.
The supplied product-line reference discusses long-life cooling, but continuous-duty limits for this full suffix must be verified from its datasheet and operating conditions.

The XG80561BX-1Q1XX-S9W is SUNON's 12 VDC, 80 × 80 × 56 mm DC blower option for servers and data-center electronics. 9.96 Pa maximum pressure is the standout documented duty-point value. Base technical purchasing on the stated catalog specification. Request the exact performance curve for final engineering signoff.
Read More
The XG60561BX-1Q248-S9W is SUNON's 0 VDC, 60 × 60 × 56 mm DC blower option for servers and data-center electronics. Its 60 × 60 × 56 mm format is the main stated selection detail. During project documentation, compare the model's operating point. Reconcile the model code with the required electrical interface.
Read More
SUNON XG80801BX-1Q061-S9T combines a 80 × 80 × 80 mm DC blower platform with a 12 VDC rating for servers and data-center electronics. Up to 203.2 m³/h is its most prominent listed performance figure. Use the documented system interface when planning technical purchasing. Request the exact performance curve for final engineering signoff.
Read More
Used in servers and data-center electronics, SUNON XG80801BX-1Q110-S9T is a 12 VDC DC blower in a 80 × 80 × 80 mm frame. Up to 199.89 m³/h is its most prominent listed performance figure. Review its cooling specification during technical purchasing. Request the exact performance curve for final engineering signoff.
Read More
Within servers and data-center electronics, SUNON XG80801BX-1Q030-S9T serves as a 80 × 80 × 80 mm DC blower operating at 12 VDC. The supplied data list 83.4 dB, an important acoustic selection parameter. Treat the duty-point values as a primary input to technical purchasing. Request the exact performance curve for final engineering signoff.
Read More
Built for servers and data-center electronics, SUNON XG80561BX-1Q010-S9T uses a 80 × 80 × 56 mm DC blower arrangement at 12 VDC. The supplied data list 83.8 dB, an important acoustic selection parameter. Treat the suffix definition as a primary input to technical purchasing. Request the exact performance curve for final engineering signoff.
Read More