Within servers and data-center electronics, SUNON XG80864BX-1Q01C-S9T serves as a 80 × 80 × 86 mm DC blower operating at 54 VDC. Up to 212.1 m³/h is its most prominent listed performance figure. During system commissioning, compare the model's pressure capability. Verify bearing and signal options in the exact datasheet.
| Rated Voltage(V) | 54 |
|---|---|
| Size(mm) | 80x80x86 |
| Max.Air Flow(m³/h) | 212.1 |
| Max.Pressure(Pa) | 11.05 |
| Speed(rpm) | 17000/15000 |
| Noise(db) | TBD |
Equipment builders can integrate SUNON XG80864BX-1Q01C-S9T, a DC brushless axial fan, into industrial equipment. The design supplies the air movement required to carry component heat out of confined spaces.
The SUNON product series carries RoHS compliance and recognized safety approvals; buyers should confirm the approval marks for this exact suffix and target market. System resistance, grille geometry and cable clearance should be reviewed together to maintain predictable air delivery.
A dependable XG80864BX-1Q01C-S9T installation starts with a review of exhaust separation. Complete wiring verification for service documentation to confirm compatibility, operating margin and the information needed for repeat orders. Match polarity, leads and control functions to the equipment harness.
Compare its listed power requirement with the required airflow and run time. Total savings depend on the complete system duty point.
The listed speed is 17000/15000 rpm. Confirm frequency, control method, and duty point for the installed system.
The supplied product-line reference discusses long-life cooling, but continuous-duty limits for this full suffix must be verified from its datasheet and operating conditions.
Keep the airflow path clear, secure the frame without distortion, and follow the exact wiring diagram and voltage rating.
Review its 80 × 80 × 86 mm size, 212.1 m³/h airflow, 11.05 Pa pressure, system resistance, and available mounting space.
The workbook marks the product as RoHS compliant. Confirm UL, TUV, VDE, or other project-specific approvals for the exact suffix.

Used in servers and data-center electronics, SUNON XG80801BX-1Q110-S9T is a 12 VDC DC blower in a 80 × 80 × 80 mm frame. Up to 199.89 m³/h is its most prominent listed performance figure. Review its cooling specification during technical purchasing. Request the exact performance curve for final engineering signoff.
Read More
Within servers and data-center electronics, SUNON XG80801BX-1Q030-S9T serves as a 80 × 80 × 80 mm DC blower operating at 12 VDC. The supplied data list 83.4 dB, an important acoustic selection parameter. Treat the duty-point values as a primary input to technical purchasing. Request the exact performance curve for final engineering signoff.
Read More
Built for servers and data-center electronics, SUNON XG80561BX-1Q010-S9T uses a 80 × 80 × 56 mm DC blower arrangement at 12 VDC. The supplied data list 83.8 dB, an important acoustic selection parameter. Treat the suffix definition as a primary input to technical purchasing. Request the exact performance curve for final engineering signoff.
Read More
A 80 × 80 × 56 mm frame and 12 VDC rating define XG80561BX-1Q03C-S9T, a DC blower for servers and data-center electronics. 9.68 Pa maximum pressure is the standout documented duty-point value. During technical purchasing, compare the model's thermal-duty record. Request the exact performance curve for final engineering signoff.
Read More
SUNON configures XG60561BX-1Q451-S9T as a 60 × 60 × 56 mm DC blower for servers and data-center electronics, operating at 12 VDC. The supplied data list 87.6 dB, an important acoustic selection parameter. Treat the pressure capability as a primary input to technical purchasing. Request the exact performance curve for final engineering signoff.
Read More
SUNON XG60561BX-1Q162-S9T combines a 60 × 60 × 56 mm DC blower platform with a 12 VDC rating for servers and data-center electronics. The supplied data list 83.1 dB, an important acoustic selection parameter. Base technical purchasing on the stated dimensional envelope. Request the exact performance curve for final engineering signoff.
Read More