EF50151B1-C02C-A99 addresses telecom cabinets, base stations, and network equipment through a 12 VDC DC blower platform measuring 50 × 50 × 15 mm. Its 7.6 m³/h airflow rating suits the stated equipment-cooling role. Base airflow-path design on the stated product configuration. Obtain the applicable curve before final duty-point approval.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 50x50x15mm |
| Max.Air Flow(m³/h) | 7.6 |
| Max.Pressure(Pa) | 166.9 |
| Input Power(W) | 1.28 |
| Speed(rpm) | 5200 |
| Noise(db) | 41 |
The SUNON EF50151B1-C02C-A99 positions a DC brushless blower for industrial equipment. Its airflow path supports heat removal from enclosed components and toward the equipment exhaust.
The SUNON product series carries RoHS compliance and recognized safety approvals; buyers should confirm the approval marks for this exact suffix and target market. The enclosure should direct air across the heat source because bypass flow can reduce cooling even when the fan runs normally.
When qualifying EF50151B1-C02C-A99, give specific attention to service access. Use prototype trials during prototype approval to align enclosure cooling, mechanical integration and lifecycle sourcing expectations. Retain access for inspection, cleaning and replacement after installation.
The supplied product-line reference discusses long-life cooling, but continuous-duty limits for this full suffix must be verified from its datasheet and operating conditions.
Keep the airflow path clear, secure the frame without distortion, and follow the exact wiring diagram and voltage rating.
The worksheet lists 1.28 W input. Check supply capacity and operating conditions before commissioning.
The workbook marks the product as RoHS compliant. Confirm UL, TUV, VDE, or other project-specific approvals for the exact suffix.
The exact IP or protection option is not stated in the supplied row. Confirm the full suffix in the applicable SUNON datasheet.

The EF50151BX-1C02C-A99 is SUNON's 12 VDC, 50 × 50 × 15 mm DC blower option for telecom cabinets, base stations, and network equipment. Its 9.2 m³/h airflow rating suits the stated equipment-cooling role. The recorded mounting size should guide mounting verification. Validate mounting and wiring from the model drawing.
Read More
SUNON EF40201BX-D03C-A99 combines a 40 × 40 × 20 mm DC axial fan platform with a 12 VDC rating for telecom cabinets, base stations, and network equipment. A listed input of 0.74 W is the model's notable electrical characteristic. For controller selection, start with the supplied performance curve. Treat bearing and life data as suffix-specific.
Read More
The EF50151B1-C03C-A99 is SUNON's 12 VDC, 50 × 50 × 15 mm DC blower option for telecom cabinets, base stations, and network equipment. Its 7.6 m³/h airflow rating suits the stated equipment-cooling role. Treat the operating point as a primary input to controller selection. Treat bearing and life data as suffix-specific.
Read More
Specified at 12 VDC, EF50151B1-C05C-A99 is a SUNON DC blower for telecom cabinets, base stations, and network equipment in 50 × 50 × 15 mm dimensions. Its 7.6 m³/h airflow rating suits the stated equipment-cooling role. Treat the application data as a primary input to mounting verification. Validate mounting and wiring from the model drawing.
Read More
SUNON configures EF50100B3-C01C-A99 as a 50 × 50 × 10 mm DC blower for telecom cabinets, base stations, and network equipment, operating at 5 VDC. A listed input of 0.61 W is the model's notable electrical characteristic. During mounting verification, compare the model's performance curve. Validate mounting and wiring from the model drawing.
Read More
SUNON EF50151B2-C03C-A99 combines a 50 × 50 × 15 mm DC blower platform with a 12 VDC rating for telecom cabinets, base stations, and network equipment. Its 5.9 m³/h airflow rating suits the stated equipment-cooling role. During airflow-path design, compare the model's system interface. Obtain the applicable curve before final duty-point approval.
Read More