Within servers and data-center electronics, SUNON PF75301B2-1B00U-A99 serves as a 75 × 75 × 30 mm DC blower operating at 12 VDC. Its 3000 rpm rating defines a lower-speed operating point. The recorded sound level should guide acoustic assessment. Match the exact part number before approving a substitute.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 75x75x30mm |
| Max.Air Flow(m³/h) | 23.4 |
| Max.Pressure(Pa) | 107.1 |
| Input Power(W) | 1.71 |
| Speed(rpm) | 3000 |
| Noise(db) | 38.6 |
SUNON PF75301B2-1B00U-A99 supports industrial equipment with DC brushless blower airflow. It is intended for installations where predictable air exchange is central to equipment stability.
The brushless DC motor architecture supports efficient electronic commutation and stable rotational performance for compact equipment cooling. Matching the fan curve to the finished airflow path supports efficient cooling without unnecessary speed or power consumption.
For PF75301B2-1B00U-A99 integration, prioritize inlet clearance. Include acoustic evaluation in engineering approval, and confirm the full model interface during prototype approval. This supports reliable cooling and traceable purchasing. Measure sound after mounting because the enclosure changes transmission.
The worksheet lists up to 23.4 m³/h. Verify the operating point against system resistance.
Keep the airflow path clear, secure the frame without distortion, and follow the exact wiring diagram and voltage rating.
The worksheet lists 1.71 W input. Check supply capacity and operating conditions before commissioning.
It is listed for servers and data-center electronics. Check dimensions, airflow, pressure, and the installation environment against the actual equipment.
The supplied row does not state the connector or lead configuration. Follow the model-specific wiring drawing.
Match voltage, dimensions, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.

For servers and data-center electronics, PF60252B2-10000-A99 combines 24 VDC operation with a 60 × 60 × 25 mm DC axial fan design. 124.5 Pa maximum pressure is the standout documented duty-point value. Use the documented speed benchmark when planning installation review. Obtain the applicable curve before final duty-point approval.
Read More
The PF60252B1-10000-A99 is SUNON's 24 VDC, 60 × 60 × 25 mm DC axial fan option for servers and data-center electronics. 139.5 Pa maximum pressure is the standout documented duty-point value. Review its airflow profile during installation review. Obtain the applicable curve before final duty-point approval.
Read More
The PF60251B3-10000-A99 is SUNON's 12 VDC, 60 × 60 × 25 mm DC axial fan option for servers and data-center electronics. 102.1 Pa maximum pressure is the standout documented duty-point value. Use the documented cooling specification when planning design qualification. Match the exact part number before approving a substitute.
Read More
For compact cooling within servers and data-center electronics, the PF60251B2-10000-A99 provides a 12 VDC DC axial fan configuration measuring 60 × 60 × 25 mm. 124.5 Pa maximum pressure is the standout documented duty-point value. Review its duty-point values during design qualification. Match the exact part number before approving a substitute.
Read More
SUNON PF60251B1-10000-A99 combines a 60 × 60 × 25 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. 139.5 Pa maximum pressure is the standout documented duty-point value. Treat the installation footprint as a primary input to design qualification. Match the exact part number before approving a substitute.
Read More
Within servers and data-center electronics, SUNON PF40561B1-10000-A9H serves as a 40 × 40 × 56 mm DC axial fan operating at 12 VDC. 657.6 Pa maximum pressure is the standout documented duty-point value. During design qualification, compare the model's rated dataset. Match the exact part number before approving a substitute.
Read More