Home > Products > By type > Axial Fans > PF60252B1-10000-A99 | SUNON 24V 2.57W 60x60x25mm 61.2m3/h DC Axial Fan for Data Center Cooling

PF60252B1-10000-A99 SUNON Axial Fan

Brand :
SUNON
Model:
PF60252B1-10000-A99 | SUNON 24V 2.57W 60x60x25mm 61.2m3/h DC Axial Fan for Data Center Cooling
Type:
Axial Fans
Industry:
Data Center Cooling
Description:

The PF60252B1-10000-A99 is SUNON's 24 VDC, 60 × 60 × 25 mm DC axial fan option for servers and data-center electronics. 139.5 Pa maximum pressure is the standout documented duty-point value. Review its airflow profile during installation review. Obtain the applicable curve before final duty-point approval.

Datasheet:
PF60252B1-10000-A99 | SUNON 24V 2.57W 60x60x25mm 61.2m3/h DC Axial Fan for Data Center Cooling Datasheet (Pdf)

Product Features

Rated Voltage(V)24
Size(mm)60x60x25mm
Max.Air Flow(m³/h)61.2
Max.Pressure(Pa)139.5
Input Power(W)2.57
Speed(rpm)7500
Noise(db)41.7

Product Features

Reliable Fan Cooling

Equipment builders can integrate SUNON PF60252B1-10000-A99, a DC brushless axial fan, into server and data-center equipment. The design supplies the air movement required to carry component heat out of confined spaces.

The brushless DC motor architecture supports efficient electronic commutation and stable rotational performance for compact equipment cooling. System resistance, grille geometry and cable clearance should be reviewed together to maintain predictable air delivery.

For PF60252B1-10000-A99 integration, prioritize inlet clearance. Include wiring verification in engineering approval, and confirm the full model interface during sourcing review. This supports reliable cooling and traceable purchasing. Match polarity, leads and control functions to the equipment harness.

Application Industry

Frequently Asked Questions

What equipment can use PF60252B1-10000-A99?

It is listed for servers and data-center electronics. Check dimensions, airflow, pressure, and the installation environment against the actual equipment.

How is PF60252B1-10000-A99 electrically connected?

The supplied row does not state the connector or lead configuration. Follow the model-specific wiring drawing.

What maintenance is recommended for PF60252B1-10000-A99?

Inspect for dust, blocked airflow, abnormal noise, loose mounting, and wiring damage. Isolate power before cleaning or service.

How can PF60252B1-10000-A99 affect operating cost?

Compare its listed 2.57 W input with the required airflow and run time. Total savings depend on the complete system duty point.

What voltage is required by PF60252B1-10000-A99?

The listed rating is 24 VDC. Verify polarity or mains frequency, wiring, and protection before commissioning.

Is PF60252B1-10000-A99 suitable for continuous operation?

The supplied product-line reference discusses long-life cooling, but continuous-duty limits for this full suffix must be verified from its datasheet and operating conditions.