The SP100A 1123XBL.GN is SUNON's 115 VAC, 120 × 120 × 38 mm AC axial fan option for commercial refrigeration and refrigerator cooling. 22 W input is the defining electrical load in the supplied data. Review its ventilation capacity during enclosure sizing. Verify bearing and signal options in the exact datasheet.
| Rated Voltage(V) | 115 |
|---|---|
| Size(mm) | 120*120*38 |
| Max.Air Flow(m³/h) | 41 |
| Input Power(W) | 22 |
| Speed(rpm) | 3150 |
| Noise(db) | 33 |
Equipment builders can integrate SUNON SP100A 1123XBL.GN, an AC axial fan, into HVAC and ventilation equipment. The design supplies the air movement required to carry component heat out of confined spaces.
The AC motor format supports direct integration with the stated supply, while the exact bearing, frequency and protection configuration remain tied to the complete part number.
To integrate SP100A 1123XBL.GN effectively, review outlet geometry at equipment level and arrange thermal-load testing before release. Confirmed system compatibility supports stable cooling and repeatable procurement. Compare installed temperatures at representative equipment loads. The final assembly should be tested under its expected thermal load.
SUNON SP100A 1123XBL.GN serves HVAC equipment. Airflow around control and heat-exchange sections helps address continuous heating and cooling loads. The fan gives OEM equipment a defined air route and supports stable air-conditioning operation. It supports reliable equipment cooling.
SUNON SP100A 1123XBL.GN serves industrial ventilation systems. Airflow around equipment air passages and thermal assemblies helps address continuous airflow demand. The fan gives OEM equipment a defined air route and supports controlled air circulation.
SUNON SP100A 1123XBL.GN serves heat-exchange equipment. Airflow around coil and exchanger surfaces helps address transferred thermal energy. The fan gives OEM equipment a defined air route and supports effective heat rejection. It supports reliable equipment cooling.
The worksheet lists up to 41 m³/h. Verify the operating point against system resistance.
The exact bearing option is not confirmed by the row-level data. Check the complete suffix in the current SUNON specification.
The worksheet lists 22 W input. Check supply capacity and operating conditions before commissioning.
The workbook marks the product as RoHS compliant. Confirm UL, TUV, VDE, or other project-specific approvals for the exact suffix.
The exact IP or protection option is not stated in the supplied row. Confirm the full suffix in the applicable SUNON datasheet.
Inspect for dust, blocked airflow, abnormal noise, loose mounting, and wiring damage. Isolate power before cleaning or service.