For servers and data-center electronics, VF80801BX-Q031-S9H combines 12 VDC operation with a 80 × 80 × 80 mm DC blower design. The supplied data list 80 dB, an important acoustic selection parameter. The recorded rated dataset should guide technical purchasing. Request the exact performance curve for final engineering signoff.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 80x80x80 |
| Max.Air Flow(m³/h) | 168.6 |
| Max.Pressure(Pa) | 6.9 |
| Input Power(W) | 112.8 |
| Speed(rpm) | 15400/13600 |
| Noise(db) | 80 |
The VF80801BX-Q031-S9H from SUNON addresses cooling needs in industrial equipment. As a DC brushless axial fan, it creates a defined inlet-to-outlet route across the thermal load.
The SUNON product series carries RoHS compliance and recognized safety approvals; buyers should confirm the approval marks for this exact suffix and target market. Correct airflow direction and inlet clearance help translate the documented operating point into reliable equipment-level cooling.
OEM teams specifying VF80801BX-Q031-S9H should check airflow direction and complete replacement-fit checks for service documentation. A documented interface review helps purchasing teams control fit, cooling continuity and replacement planning. Verify orientation so heated air does not recirculate through the inlet.
It is listed for servers and data-center electronics. Check dimensions, airflow, pressure, and the installation environment against the actual equipment.
The supplied row does not state the connector or lead configuration. Follow the model-specific wiring drawing.
Speed-control capability is not stated for this complete part number. Confirm the signal and controller requirements before use.
Compare its listed 112.8 W input with the required airflow and run time. Total savings depend on the complete system duty point.
The worksheet lists 80 dB. Installation distance, airflow resistance, and enclosure acoustics can change the measured result.

SUNON VF80864BX-Q023-S9H combines a 80 × 80 × 86 mm DC blower platform with a 54 VDC rating for servers and data-center electronics. The supplied data list 81.9 dB, an important acoustic selection parameter. Review its speed benchmark during system commissioning. Verify bearing and signal options in the exact datasheet.
Read More
Applied in servers and data-center electronics, SUNON VF80761BX-Q040-S9H is a 12 VDC DC blower in a 80 × 80 × 76 mm frame. The supplied data list 78.8 dB, an important acoustic selection parameter. Use the documented ventilation capacity when planning technical purchasing. Request the exact performance curve for final engineering signoff.
Read More
SUNON VF92381BX-D020-S9H combines a 92 × 92 × 38 mm DC blower platform with a 12 VDC rating for servers and data-center electronics. 4.48 Pa maximum pressure is the standout documented duty-point value. Treat the cooling output as a primary input to system commissioning. Verify bearing and signal options in the exact datasheet.
Read More
VF80864BX-1Q010-S9H serves servers and data-center electronics as a 80 × 80 × 86 mm DC blower rated at 54 VDC. The supplied data list 87.3 dB, an important acoustic selection parameter. Use the documented electrical load when planning system commissioning. Verify bearing and signal options in the exact datasheet.
Read More
The VF80804BX-1Q040-S9H is SUNON's 54 VDC, 80 × 80 × 80 mm DC blower option for servers and data-center electronics. The supplied data list 84.6 dB, an important acoustic selection parameter. During technical purchasing, compare the model's selection parameters. Request the exact performance curve for final engineering signoff.
Read More
Within servers and data-center electronics, SUNON VF80561BX-Q11C-S9H serves as a 80 × 80 × 56 mm DC blower operating at 12 VDC. 3.57 Pa maximum pressure is the standout documented duty-point value. Use the documented supply requirement when planning technical purchasing. Request the exact performance curve for final engineering signoff.
Read More