Sized for servers and data-center electronics, SUNON XG43564BX-1Q010-S9I is a 50 VDC DC blower in a 43 × 43 × 56 mm frame. Its 4.9 m³/h airflow rating suits the stated equipment-cooling role. Treat the selection parameters as a primary input to application screening. Validate approvals and protection at complete-part-number level.
| Rated Voltage(V) | 50 |
|---|---|
| Size(mm) | 43x43x56 |
| Max.Air Flow(m³/h) | 4.9 |
| Max.Pressure(Pa) | 11.5 |
| Speed(rpm) | 30000/30000 |
| Noise(db) | TBD |
The XG43564BX-1Q010-S9I from SUNON addresses cooling needs in industrial equipment. As a DC brushless axial fan, it creates a defined inlet-to-outlet route across the thermal load.
The SUNON product series carries RoHS compliance and recognized safety approvals; buyers should confirm the approval marks for this exact suffix and target market. Correct airflow direction and inlet clearance help translate the documented operating point into reliable equipment-level cooling.
Before adopting XG43564BX-1Q010-S9I, engineers should evaluate mounting rigidity. Carry out power-budget review for service documentation so the chosen fan can be released with clear installation and sourcing requirements. Use a firm support surface to limit movement at the fan frame.
The supplied row does not state the connector or lead configuration. Follow the model-specific wiring drawing.
Speed-control capability is not stated for this complete part number. Confirm the signal and controller requirements before use.
Its documented 50 VDC rating and its 4.9 m³/h airflow rating suits the stated equipment-cooling role. allow comparison with the required duty point without assuming unlisted options.
The listed rating is 50 VDC. Verify polarity or mains frequency, wiring, and protection before commissioning.
The worksheet lists up to 4.9 m³/h. Verify the operating point against system resistance.

Within servers and data-center electronics, SUNON XG40561BX-1QA90-S9I serves as a 40 × 40 × 56 mm DC blower operating at 12 VDC. The supplied data list 85.5 dB, an important acoustic selection parameter. Base application screening on the stated rated dataset. Validate approvals and protection at complete-part-number level.
Read More
Equipment designers working with servers and data-center electronics can evaluate SUNON XG60561BX-1Q029-S9I, a DC blower rated at 0 VDC and sized 60 × 60 × 56 mm. Its 60 × 60 × 56 mm format is the main stated selection detail. Base project documentation on the stated cooling output. Reconcile the model code with the required electrical interface.
Read More
SUNON XG80801BX-1Q061-S9T combines a 80 × 80 × 80 mm DC blower platform with a 12 VDC rating for servers and data-center electronics. Up to 203.2 m³/h is its most prominent listed performance figure. Use the documented system interface when planning technical purchasing. Request the exact performance curve for final engineering signoff.
Read More
Used in servers and data-center electronics, SUNON XG80801BX-1Q110-S9T is a 12 VDC DC blower in a 80 × 80 × 80 mm frame. Up to 199.89 m³/h is its most prominent listed performance figure. Review its cooling specification during technical purchasing. Request the exact performance curve for final engineering signoff.
Read More
Within servers and data-center electronics, SUNON XG80801BX-1Q030-S9T serves as a 80 × 80 × 80 mm DC blower operating at 12 VDC. The supplied data list 83.4 dB, an important acoustic selection parameter. Treat the duty-point values as a primary input to technical purchasing. Request the exact performance curve for final engineering signoff.
Read More
Within servers and data-center electronics, SUNON XG80564BX-1Q010-S9W serves as a 80 × 80 × 56 mm DC blower operating at 51 VDC. The supplied data list 87.2 dB, an important acoustic selection parameter. Review its equipment fit during technical purchasing. Request the exact performance curve for final engineering signoff.
Read More