The XG60561BX-1Q011-S9H is SUNON's 12 VDC, 60 × 60 × 56 mm DC blower option for servers and data-center electronics. The supplied data list 78.3 dB, an important acoustic selection parameter. Use the documented airflow profile when planning technical purchasing. Request the exact performance curve for final engineering signoff.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 60x60x56 |
| Max.Air Flow(m³/h) | 83.3 |
| Max.Pressure(Pa) | 9.31 |
| Input Power(W) | 52.8 |
| Speed(rpm) | 23000/22000 |
| Noise(db) | 78.3 |
SUNON XG60561BX-1Q011-S9H supports server and data-center equipment with DC brushless axial fan airflow. It is intended for installations where predictable air exchange is central to equipment stability.
The SUNON product series carries RoHS compliance and recognized safety approvals; buyers should confirm the approval marks for this exact suffix and target market.
For XG60561BX-1Q011-S9H integration, prioritize inlet clearance. Include environmental checks in engineering approval, and confirm the full model interface for service documentation. This supports reliable cooling and traceable purchasing. Check that the selected variant suits the specified operating surroundings. The final assembly should be tested under its expected thermal load.
SUNON XG60561BX-1Q011-S9H serves server platforms. Airflow around processors, memory and power components helps address sustained computing loads. The fan gives OEM equipment a defined air route and supports stable server operation. It supports reliable equipment cooling.
SUNON XG60561BX-1Q011-S9H serves storage equipment. Airflow around drives, controllers and power assemblies helps address continuous data workloads. The fan gives OEM equipment a defined air route and supports reliable storage availability. It supports reliable equipment cooling.
SUNON XG60561BX-1Q011-S9H serves edge-computing systems. Airflow around compact processing and communication modules helps address high heat density. The fan gives OEM equipment a defined air route and supports consistent thermal control. It supports reliable equipment cooling.
SUNON XG60561BX-1Q011-S9H serves data-center equipment. Airflow around critical computing assemblies helps address round-the-clock heat generation. The fan gives OEM equipment a defined air route and supports infrastructure availability. It supports reliable equipment cooling.
Compare its listed 52.8 W input with the required airflow and run time. Total savings depend on the complete system duty point.
The worksheet lists 78.3 dB. Installation distance, airflow resistance, and enclosure acoustics can change the measured result.
The worksheet lists up to 83.3 m³/h. Verify the operating point against system resistance.
The exact bearing option is not confirmed by the row-level data. Check the complete suffix in the current SUNON specification.
Review its 60 × 60 × 56 mm size, 83.3 m³/h airflow, 9.31 Pa pressure, system resistance, and available mounting space.
Assess reliability from the exact bearing, temperature, protection, and life data. The supplied series note alone does not confirm every suffix-specific option.

Configured for servers and data-center electronics, SUNON XG60561BX-1Q160-S9H is a 12 VDC DC blower in a 60 × 60 × 56 mm frame. The supplied data list 85.5 dB, an important acoustic selection parameter. During technical purchasing, compare the model's acoustic value. Request the exact performance curve for final engineering signoff.
Read More
Within servers and data-center electronics, SUNON XG60561BX-1Q017-S9H serves as a 60 × 60 × 56 mm DC blower operating at 12 VDC. The supplied data list 81.3 dB, an important acoustic selection parameter. The recorded electrical load should guide technical purchasing. Request the exact performance curve for final engineering signoff.
Read More
For servers and data-center electronics, XG60561BX-1Q081-S9H combines 12 VDC operation with a 60 × 60 × 56 mm DC blower design. The supplied data list 76.6 dB, an important acoustic selection parameter. For technical purchasing, start with the supplied speed benchmark. Request the exact performance curve for final engineering signoff.
Read More
SUNON XG40561BX-1Q962-S9H is a 12 VDC DC blower in a 40 × 40 × 56 mm format for servers and data-center electronics. The supplied data list 76.1 dB, an important acoustic selection parameter. During application screening, compare the model's motor input. Validate approvals and protection at complete-part-number level.
Read More
The 40 × 40 × 56 mm XG40561BX-1Q490-S9H brings 12 VDC DC blower cooling to servers and data-center electronics. 7.2 Pa maximum pressure is the standout documented duty-point value. For application screening, start with the supplied equipment fit. Validate approvals and protection at complete-part-number level.
Read More
SUNON XG40561BX-1Q840-S9H combines a 40 × 40 × 56 mm DC blower platform with a 12 VDC rating for servers and data-center electronics. The supplied data list 76.1 dB, an important acoustic selection parameter. Use the documented suffix definition when planning application screening. Validate approvals and protection at complete-part-number level.
Read More