Configured for servers and data-center electronics, SUNON XG60561BX-1Q160-S9H is a 12 VDC DC blower in a 60 × 60 × 56 mm frame. The supplied data list 85.5 dB, an important acoustic selection parameter. During technical purchasing, compare the model's acoustic value. Request the exact performance curve for final engineering signoff.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 60x60x56 |
| Max.Air Flow(m³/h) | 106.2 |
| Max.Pressure(Pa) | 12.97 |
| Input Power(W) | 82.8 |
| Speed(rpm) | 24600/24200 |
| Noise(db) | 85.5 |
The SUNON XG60561BX-1Q160-S9H positions a DC brushless axial fan for industrial equipment. Its airflow path supports heat removal from enclosed components and toward the equipment exhaust.
The SUNON product series carries RoHS compliance and recognized safety approvals; buyers should confirm the approval marks for this exact suffix and target market. Correct airflow direction and inlet clearance help translate the documented operating point into reliable equipment-level cooling.
XG60561BX-1Q160-S9H is best integrated with attention to grille resistance. Engineering teams can use environmental checks for service documentation to verify thermal suitability and give buyers an auditable selection basis. Account for the pressure loss introduced by guards and protective screens.
The workbook marks the product as RoHS compliant. Confirm UL, TUV, VDE, or other project-specific approvals for the exact suffix.
Confirm any missing bearing, connector, control, IP rating, life, certification, and performance-curve details for the complete part number.
Speed-control capability is not stated for this complete part number. Confirm the signal and controller requirements before use.
Compare its listed 82.8 W input with the required airflow and run time. Total savings depend on the complete system duty point.
The listed speed is 24600/24200 rpm. Confirm frequency, control method, and duty point for the installed system.

Within servers and data-center electronics, SUNON XG60561BX-1Q017-S9H serves as a 60 × 60 × 56 mm DC blower operating at 12 VDC. The supplied data list 81.3 dB, an important acoustic selection parameter. The recorded electrical load should guide technical purchasing. Request the exact performance curve for final engineering signoff.
Read More
For servers and data-center electronics, XG60561BX-1Q081-S9H combines 12 VDC operation with a 60 × 60 × 56 mm DC blower design. The supplied data list 76.6 dB, an important acoustic selection parameter. For technical purchasing, start with the supplied speed benchmark. Request the exact performance curve for final engineering signoff.
Read More
The XG60561BX-1Q011-S9H is SUNON's 12 VDC, 60 × 60 × 56 mm DC blower option for servers and data-center electronics. The supplied data list 78.3 dB, an important acoustic selection parameter. Use the documented airflow profile when planning technical purchasing. Request the exact performance curve for final engineering signoff.
Read More
SUNON XG40561BX-1Q962-S9H is a 12 VDC DC blower in a 40 × 40 × 56 mm format for servers and data-center electronics. The supplied data list 76.1 dB, an important acoustic selection parameter. During application screening, compare the model's motor input. Validate approvals and protection at complete-part-number level.
Read More
The 40 × 40 × 56 mm XG40561BX-1Q490-S9H brings 12 VDC DC blower cooling to servers and data-center electronics. 7.2 Pa maximum pressure is the standout documented duty-point value. For application screening, start with the supplied equipment fit. Validate approvals and protection at complete-part-number level.
Read More
SUNON XG40561BX-1Q840-S9H combines a 40 × 40 × 56 mm DC blower platform with a 12 VDC rating for servers and data-center electronics. The supplied data list 76.1 dB, an important acoustic selection parameter. Use the documented suffix definition when planning application screening. Validate approvals and protection at complete-part-number level.
Read More