The EF60252S1-1000U-A99 is SUNON's 24 VDC, 60 × 60 × 25 mm DC axial fan option for telecom cabinets, base stations, and network equipment. A listed noise value of 27 dB is the model's key differentiator. Base wiring review on the stated ventilation capacity. Confirm environmental protection for the ordered version.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 60x60x25 |
| Max.Air Flow(m³/h) | 39.9 |
| Max.Pressure(Pa) | 52.3 |
| Input Power(W) | 1.2 |
| Speed(rpm) | 4500 |
| Noise(db) | 27 |
Equipment builders can integrate SUNON EF60252S1-1000U-A99, a DC brushless axial fan, into industrial equipment. The design supplies the air movement required to carry component heat out of confined spaces.
The SUNON product series carries RoHS compliance and recognized safety approvals; buyers should confirm the approval marks for this exact suffix and target market. Correct airflow direction and inlet clearance help translate the documented operating point into reliable equipment-level cooling.
To integrate EF60252S1-1000U-A99 effectively, review outlet geometry at equipment level and arrange airflow mapping before ordering. Confirmed system compatibility supports stable cooling and repeatable procurement. Review circulation around the components most sensitive to heat.
The supplied row does not state the connector or lead configuration. Follow the model-specific wiring drawing.
Speed-control capability is not stated for this complete part number. Confirm the signal and controller requirements before use.
Compare its listed 1.2 W input with the required airflow and run time. Total savings depend on the complete system duty point.
The listed rating is 24 VDC. Verify polarity or mains frequency, wiring, and protection before commissioning.
The worksheet lists up to 39.9 m³/h. Verify the operating point against system resistance.
Yes. The worksheet lists up to 52.3 Pa; compare it with the system curve.

The EF80251S1-1000U-A99 is SUNON's 12 VDC, 80 × 80 × 25 mm DC axial fan option for telecom cabinets, base stations, and network equipment. Its 3200 rpm rating defines a lower-speed operating point. During airflow balancing, compare the model's volume-flow figure. Review connector, alarm, and sensor options separately.
Read More
EF40101B1-1000U-A99 serves telecom cabinets, base stations, and network equipment as a 40 × 40 × 10 mm DC axial fan rated at 12 VDC. Its 13.6 m³/h airflow rating suits the stated equipment-cooling role. Base airflow balancing on the stated static-pressure entry. Review connector, alarm, and sensor options separately.
Read More
Within telecom cabinets, base stations, and network equipment, EF50152B1-1C01U-A99 provides a 50 × 50 × 15 mm, 24 VDC DC blower configuration. A listed input of 1.11 W is the model's notable electrical characteristic. Treat the dimensional envelope as a primary input to mounting verification. Validate mounting and wiring from the model drawing.
Read More
For telecom cabinets, base stations, and network equipment, EF60202B3-000U-A99 combines 24 VDC operation with a 60 × 60 × 20 mm DC axial fan design. A listed input of 0.56 W is the model's notable electrical characteristic. Base airflow-path design on the stated speed benchmark. Obtain the applicable curve before final duty-point approval.
Read More
EF60150S2-C01C-S99 serves telecom cabinets, base stations, and network equipment as a size not stated DC blower rated at 5 VDC. A listed input of 1.98 W is the model's notable electrical characteristic. Review its electrical load during wiring review. Confirm environmental protection for the ordered version.
Read More
Built for telecom cabinets, base stations, and network equipment, SUNON EF80152B1-EE070-S99 uses a 80 × 80 × 15 mm DC blower arrangement at 24 VDC. 2.16 W input is the defining electrical load in the supplied data. Treat the frame geometry as a primary input to wiring review. Confirm environmental protection for the ordered version.
Read More