The EF80251S1-1000U-A99 is SUNON's 12 VDC, 80 × 80 × 25 mm DC axial fan option for telecom cabinets, base stations, and network equipment. Its 3200 rpm rating defines a lower-speed operating point. During airflow balancing, compare the model's volume-flow figure. Review connector, alarm, and sensor options separately.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 80*80*25 |
| Max.Air Flow(m³/h) | 69.7 |
| Input Power(W) | 1.44 |
| Speed(rpm) | 3200 |
| Noise(db) | 33 |
Equipment builders can integrate SUNON EF80251S1-1000U-A99, a DC brushless axial fan, into industrial equipment. The design supplies the air movement required to carry component heat out of confined spaces.
SUNON's DC product line is developed around MagLev motor technology, supporting low-friction rotation, energy-conscious operation and long service life in compact formats.
OEM teams specifying EF80251S1-1000U-A99 should check airflow direction and complete maintenance planning in equipment qualification. A documented interface review helps purchasing teams control fit, cooling continuity and replacement planning. Define cleaning and inspection intervals around the actual duty cycle. The final assembly should be tested under its expected thermal load.
Inspect for dust, blocked airflow, abnormal noise, loose mounting, and wiring damage. Isolate power before cleaning or service.
Its documented 12 VDC rating and its 3200 rpm rating defines a lower-speed operating point. allow comparison with the required duty point without assuming unlisted options.
The listed rating is 12 VDC. Verify polarity or mains frequency, wiring, and protection before commissioning.
The worksheet lists up to 69.7 m³/h. Verify the operating point against system resistance.
No pressure value is provided in the worksheet. Request the model-specific performance curve if pressure is critical.
Review its 80 × 80 × 25 mm size, 69.7 m³/h airflow, system resistance, and available mounting space.

The EF60252S1-1000U-A99 is SUNON's 24 VDC, 60 × 60 × 25 mm DC axial fan option for telecom cabinets, base stations, and network equipment. A listed noise value of 27 dB is the model's key differentiator. Base wiring review on the stated ventilation capacity. Confirm environmental protection for the ordered version.
Read More
EF40101B1-1000U-A99 serves telecom cabinets, base stations, and network equipment as a 40 × 40 × 10 mm DC axial fan rated at 12 VDC. Its 13.6 m³/h airflow rating suits the stated equipment-cooling role. Base airflow balancing on the stated static-pressure entry. Review connector, alarm, and sensor options separately.
Read More
Within telecom cabinets, base stations, and network equipment, EF50152B1-1C01U-A99 provides a 50 × 50 × 15 mm, 24 VDC DC blower configuration. A listed input of 1.11 W is the model's notable electrical characteristic. Treat the dimensional envelope as a primary input to mounting verification. Validate mounting and wiring from the model drawing.
Read More
For telecom cabinets, base stations, and network equipment, EF60202B3-000U-A99 combines 24 VDC operation with a 60 × 60 × 20 mm DC axial fan design. A listed input of 0.56 W is the model's notable electrical characteristic. Base airflow-path design on the stated speed benchmark. Obtain the applicable curve before final duty-point approval.
Read More
EF60150S2-C01C-S99 serves telecom cabinets, base stations, and network equipment as a size not stated DC blower rated at 5 VDC. A listed input of 1.98 W is the model's notable electrical characteristic. Review its electrical load during wiring review. Confirm environmental protection for the ordered version.
Read More
Built for telecom cabinets, base stations, and network equipment, SUNON EF80152B1-EE070-S99 uses a 80 × 80 × 15 mm DC blower arrangement at 24 VDC. 2.16 W input is the defining electrical load in the supplied data. Treat the frame geometry as a primary input to wiring review. Confirm environmental protection for the ordered version.
Read More