For ventilation needs in servers and data-center electronics, the PF60251VX-10000-A99 provides a 12 VDC DC axial fan configuration measuring 60 × 60 × 25 mm. 8300 rpm is the model's most distinctive operating parameter. Treat the application data as a primary input to design qualification. Match the exact part number before approving a substitute.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 60x60x25mm |
| Max.Air Flow(m³/h) | 68 |
| Max.Pressure(Pa) | 164.4 |
| Input Power(W) | 4.08 |
| Speed(rpm) | 8300 |
| Noise(db) | 46 |
SUNON PF60251VX-10000-A99 brings active air movement to server and data-center equipment. This DC brushless axial fan helps equipment designers control thermal conditions around densely arranged parts.
SUNON's DC product line is developed around MagLev motor technology, supporting low-friction rotation, energy-conscious operation and long service life in compact formats.
To integrate PF60251VX-10000-A99 effectively, review outlet geometry at equipment level and arrange replacement-fit checks during sourcing review. Confirmed system compatibility supports stable cooling and repeatable procurement. Preserve a clear discharge region to avoid unnecessary downstream turbulence. The final assembly should be tested under its expected thermal load.
SUNON PF60251VX-10000-A99 serves server platforms. Airflow around processors, memory and power components helps address sustained computing loads. The fan gives OEM equipment a defined air route and supports stable server operation. It supports reliable equipment cooling.
SUNON PF60251VX-10000-A99 serves storage equipment. Airflow around drives, controllers and power assemblies helps address continuous data workloads. The fan gives OEM equipment a defined air route and supports reliable storage availability. It supports reliable equipment cooling.
SUNON PF60251VX-10000-A99 serves edge-computing systems. Airflow around compact processing and communication modules helps address high heat density. The fan gives OEM equipment a defined air route and supports consistent thermal control. It supports reliable equipment cooling.
SUNON PF60251VX-10000-A99 serves data-center equipment. Airflow around critical computing assemblies helps address round-the-clock heat generation. The fan gives OEM equipment a defined air route and supports infrastructure availability. It supports reliable equipment cooling.
Yes. The worksheet lists up to 164.4 Pa; compare it with the system curve.
The worksheet lists 4.08 W input. Check supply capacity and operating conditions before commissioning.
The workbook marks the product as RoHS compliant. Confirm UL, TUV, VDE, or other project-specific approvals for the exact suffix.
The supplied row does not state the connector or lead configuration. Follow the model-specific wiring drawing.
Inspect for dust, blocked airflow, abnormal noise, loose mounting, and wiring damage. Isolate power before cleaning or service.

A 60 × 60 × 25 mm frame and 12 VDC rating define PF60251BX-10000-A99, a DC axial fan for servers and data-center electronics. 8300 rpm is the model's most distinctive operating parameter. For design qualification, start with the supplied system interface. Match the exact part number before approving a substitute.
Read More
Within servers and data-center electronics, SUNON PF60252B3-10000-A99 serves as a 60 × 60 × 25 mm DC axial fan operating at 24 VDC. 102.1 Pa maximum pressure is the standout documented duty-point value. For installation review, start with the supplied electrical load. Obtain the applicable curve before final duty-point approval.
Read More
For servers and data-center electronics, PF60252B2-10000-A99 combines 24 VDC operation with a 60 × 60 × 25 mm DC axial fan design. 124.5 Pa maximum pressure is the standout documented duty-point value. Use the documented speed benchmark when planning installation review. Obtain the applicable curve before final duty-point approval.
Read More
The PF60252B1-10000-A99 is SUNON's 24 VDC, 60 × 60 × 25 mm DC axial fan option for servers and data-center electronics. 139.5 Pa maximum pressure is the standout documented duty-point value. Review its airflow profile during installation review. Obtain the applicable curve before final duty-point approval.
Read More
SUNON PF60251V3-10000-A99 combines a 60 × 60 × 25 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. 102.1 Pa maximum pressure is the standout documented duty-point value. Base design qualification on the stated technical profile. Match the exact part number before approving a substitute.
Read More
Configured for servers and data-center electronics, SUNON PF60251V2-10000-A99 is a 12 VDC DC axial fan in a 60 × 60 × 25 mm frame. 124.5 Pa maximum pressure is the standout documented duty-point value. During design qualification, compare the model's model record. Match the exact part number before approving a substitute.
Read More