PF60252B3-10000-A99 SUNON Axial Fan

Brand :
SUNON
Model:
PF60252B3-10000-A99 | SUNON 24V 1.56W 60x60x25mm 49.3m3/h DC Axial Fan for Data Center Cooling
Type:
Axial Fans
Industry:
Data Center Cooling
Description:

Within servers and data-center electronics, SUNON PF60252B3-10000-A99 serves as a 60 × 60 × 25 mm DC axial fan operating at 24 VDC. 102.1 Pa maximum pressure is the standout documented duty-point value. For installation review, start with the supplied electrical load. Obtain the applicable curve before final duty-point approval.

Datasheet:
PF60252B3-10000-A99 | SUNON 24V 1.56W 60x60x25mm 49.3m3/h DC Axial Fan for Data Center Cooling Datasheet (Pdf)

Product Features

Rated Voltage(V)24
Size(mm)60x60x25mm
Max.Air Flow(m³/h)49.3
Max.Pressure(Pa)102.1
Input Power(W)1.56
Speed(rpm)6200
Noise(db)37.5

Product Features

Reliable Fan Cooling

SUNON PF60252B3-10000-A99 supports server and data-center equipment with DC brushless axial fan airflow. It is intended for installations where predictable air exchange is central to equipment stability.

The brushless DC motor architecture supports efficient electronic commutation and stable rotational performance for compact equipment cooling. System resistance, grille geometry and cable clearance should be reviewed together to maintain predictable air delivery.

Before adopting PF60252B3-10000-A99, engineers should evaluate mounting rigidity. Carry out wiring verification during sourcing review so the chosen fan can be released with clear installation and sourcing requirements. Match polarity, leads and control functions to the equipment harness.

Application Industry

Frequently Asked Questions

What installation checks apply to PF60252B3-10000-A99?

Keep the airflow path clear, secure the frame without distortion, and follow the exact wiring diagram and voltage rating.

Which performance figures define PF60252B3-10000-A99?

Use the listed voltage, size, 49.3 m³/h airflow, 6200 rpm, and 1.56 W input for preliminary comparison.

What equipment can use PF60252B3-10000-A99?

It is listed for servers and data-center electronics. Check dimensions, airflow, pressure, and the installation environment against the actual equipment.

What protection rating does PF60252B3-10000-A99 have?

The exact IP or protection option is not stated in the supplied row. Confirm the full suffix in the applicable SUNON datasheet.

What maintenance is recommended for PF60252B3-10000-A99?

Inspect for dust, blocked airflow, abnormal noise, loose mounting, and wiring damage. Isolate power before cleaning or service.

How can PF60252B3-10000-A99 affect operating cost?

Compare its listed 1.56 W input with the required airflow and run time. Total savings depend on the complete system duty point.

Message Form