The PF70201V1-1Q01U-S99 is SUNON's 12 VDC, 70 × 70 × 20 mm DC blower option for servers and data-center electronics. Up to 73.1 m³/h is its most prominent listed performance figure. During design qualification, compare the model's power demand. Match the exact part number before approving a substitute.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 70x70x20mm |
| Max.Air Flow(m³/h) | 73.1 |
| Max.Pressure(Pa) | 69.7 |
| Input Power(W) | 3.42 |
| Speed(rpm) | 4600 |
| Noise(db) | 41.5 |
Equipment builders can integrate SUNON PF70201V1-1Q01U-S99, a DC brushless axial fan, into industrial equipment. The design supplies the air movement required to carry component heat out of confined spaces.
The SUNON product series carries RoHS compliance and recognized safety approvals; buyers should confirm the approval marks for this exact suffix and target market.
Design approval for PF70201V1-1Q01U-S99 should cover cable routing together with environmental checks during sourcing review. This creates a practical link between thermal validation, purchasing documentation and future servicing. Check that the selected variant suits the specified operating surroundings. The final assembly should be tested under its expected thermal load.
Speed-control capability is not stated for this complete part number. Confirm the signal and controller requirements before use.
Stock and lead time can change. Confirm the exact suffix, quantity, and delivery date with the supplier before ordering.
The worksheet lists 41.5 dB. Installation distance, airflow resistance, and enclosure acoustics can change the measured result.
Verify supply, wiring, obstructions, impeller movement, and protection status. Use the model datasheet before replacement or repair.
Keep the airflow path clear, secure the frame without distortion, and follow the exact wiring diagram and voltage rating.
Use the listed voltage, size, 73.1 m³/h airflow, 4600 rpm, and 3.42 W input for preliminary comparison.

Built around servers and data-center electronics, SUNON PF80251B3-1000U-S99 is a 12 VDC DC axial fan in a 80 × 80 × 25 mm frame. Up to 90.1 m³/h is its most prominent listed performance figure. Review its acoustic value during airflow-path design. Obtain the applicable curve before final duty-point approval.
Read More
A 80 × 80 × 25 mm frame and 24 VDC rating define PF80252B1-1000U-S99, a DC axial fan for servers and data-center electronics. Up to 102 m³/h is its most prominent listed performance figure. Treat the system interface as a primary input to acoustic assessment. Match the exact part number before approving a substitute.
Read More
SUNON PF60251V3-10000-A99 combines a 60 × 60 × 25 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. 102.1 Pa maximum pressure is the standout documented duty-point value. Base design qualification on the stated technical profile. Match the exact part number before approving a substitute.
Read More
Configured for servers and data-center electronics, SUNON PF60251V2-10000-A99 is a 12 VDC DC axial fan in a 60 × 60 × 25 mm frame. 124.5 Pa maximum pressure is the standout documented duty-point value. During design qualification, compare the model's model record. Match the exact part number before approving a substitute.
Read More
Within servers and data-center electronics, SUNON PF60251V1-10000-A99 serves as a 60 × 60 × 25 mm DC axial fan operating at 12 VDC. 139.5 Pa maximum pressure is the standout documented duty-point value. The recorded product configuration should guide design qualification. Match the exact part number before approving a substitute.
Read More
Equipment designers working with servers and data-center electronics can evaluate SUNON PF40281V1-0000-A99, a DC axial fan rated at 12 VDC and sized 40 × 40 × 28 mm. 17600 rpm is the model's most distinctive operating parameter. The recorded motor input should guide design qualification. Match the exact part number before approving a substitute.
Read More