Within servers and data-center electronics, SUNON PF60251V1-10000-A99 serves as a 60 × 60 × 25 mm DC axial fan operating at 12 VDC. 139.5 Pa maximum pressure is the standout documented duty-point value. The recorded product configuration should guide design qualification. Match the exact part number before approving a substitute.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 60x60x25mm |
| Max.Air Flow(m³/h) | 61.2 |
| Max.Pressure(Pa) | 139.5 |
| Input Power(W) | 3.1 |
| Speed(rpm) | 7500 |
| Noise(db) | 41.7 |
Designed for server and data-center equipment, the SUNON PF60251V1-10000-A99 provides DC brushless axial fan cooling in a format suited to equipment integration. It helps limit local heat buildup during operation.
SUNON's DC product line is developed around MagLev motor technology, supporting low-friction rotation, energy-conscious operation and long service life in compact formats.
When qualifying PF60251V1-10000-A99, give specific attention to service access. Use replacement-fit checks during sourcing review to align enclosure cooling, mechanical integration and lifecycle sourcing expectations. Verify mounting, connector and airflow direction against the replacement space. The final assembly should be tested under its expected thermal load.
SUNON PF60251V1-10000-A99 serves server platforms. Airflow around processors, memory and power components helps address sustained computing loads. The fan gives OEM equipment a defined air route and supports stable server operation. It supports reliable equipment cooling.
SUNON PF60251V1-10000-A99 serves storage equipment. Airflow around drives, controllers and power assemblies helps address continuous data workloads. The fan gives OEM equipment a defined air route and supports reliable storage availability. It supports reliable equipment cooling.
SUNON PF60251V1-10000-A99 serves edge-computing systems. Airflow around compact processing and communication modules helps address high heat density. The fan gives OEM equipment a defined air route and supports consistent thermal control. It supports reliable equipment cooling.
SUNON PF60251V1-10000-A99 serves data-center equipment. Airflow around critical computing assemblies helps address round-the-clock heat generation. The fan gives OEM equipment a defined air route and supports infrastructure availability. It supports reliable equipment cooling.
Verify supply, wiring, obstructions, impeller movement, and protection status. Use the model datasheet before replacement or repair.
Yes. The worksheet lists up to 139.5 Pa; compare it with the system curve.
Review its 60 × 60 × 25 mm size, 61.2 m³/h airflow, 139.5 Pa pressure, system resistance, and available mounting space.
Assess reliability from the exact bearing, temperature, protection, and life data. The supplied series note alone does not confirm every suffix-specific option.
The supplied row does not state the connector or lead configuration. Follow the model-specific wiring drawing.
Speed-control capability is not stated for this complete part number. Confirm the signal and controller requirements before use.

The PF60252B1-10000-A99 is SUNON's 24 VDC, 60 × 60 × 25 mm DC axial fan option for servers and data-center electronics. 139.5 Pa maximum pressure is the standout documented duty-point value. Review its airflow profile during installation review. Obtain the applicable curve before final duty-point approval.
Read More
SUNON PF60251B1-10000-A99 combines a 60 × 60 × 25 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. 139.5 Pa maximum pressure is the standout documented duty-point value. Treat the installation footprint as a primary input to design qualification. Match the exact part number before approving a substitute.
Read More
Within servers and data-center electronics, SUNON PF60252B3-10000-A99 serves as a 60 × 60 × 25 mm DC axial fan operating at 24 VDC. 102.1 Pa maximum pressure is the standout documented duty-point value. For installation review, start with the supplied electrical load. Obtain the applicable curve before final duty-point approval.
Read More
For servers and data-center electronics, PF60252B2-10000-A99 combines 24 VDC operation with a 60 × 60 × 25 mm DC axial fan design. 124.5 Pa maximum pressure is the standout documented duty-point value. Use the documented speed benchmark when planning installation review. Obtain the applicable curve before final duty-point approval.
Read More
For ventilation needs in servers and data-center electronics, the PF60251VX-10000-A99 provides a 12 VDC DC axial fan configuration measuring 60 × 60 × 25 mm. 8300 rpm is the model's most distinctive operating parameter. Treat the application data as a primary input to design qualification. Match the exact part number before approving a substitute.
Read More
SUNON PF60251V3-10000-A99 combines a 60 × 60 × 25 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. 102.1 Pa maximum pressure is the standout documented duty-point value. Base design qualification on the stated technical profile. Match the exact part number before approving a substitute.
Read More