Get Quote
Home > Products > By type > Blower Fans > AFB0412HHB | Delta Electronics 12VDC 1.56W Axial Fan for Server and Power Supply Cooling

AFB0412HHB Delta Blower Fan

Brand :
Delta
Model:
AFB0412HHB | Delta Electronics 12VDC 1.56W Axial Fan for Server and Power Supply Cooling
Type:
Blower Fans
Industry:
Data Center Cooling
Description:

AFB0412HHB pairs a listed 1.56 W input with an 8300 rpm axial fan rotor for server and power-supply cooling. Powered by 12VDC, the 40 x 40 x 15 mm assembly has a maximum static-pressure rating of 89.4 Pa.

Datasheet:
AFB0412HHB | Delta Electronics 12VDC 1.56W Axial Fan for Server and Power Supply Cooling Datasheet (Pdf)

Product Features

Rated Voltage(V)12
Size(mm)40x40x15
Max.Air Flow(m³/h)19.3
Max.Pressure(Pa)89.4
Input Power(W)1.56
Speed(rpm)8300
Noise(db)32

Product Features

Quiet Duty Cooling

The Delta AFB0412HHB is a brushless DC axial fan for server and storage equipment. It provides a defined airflow path where equipment layout leaves limited room for passive heat removal.

A listed speed of 8300 rpm helps define the operating profile when reviewing airflow demand, mechanical mounting and the enclosure's acoustic target. The series uses ball-bearing motor support for rotational durability, giving OEMs a service-life-oriented construction for equipment cooling. Separating the intake from warmed exhaust improves the effectiveness of air exchange across the equipment section.

For system integrators, a confirmed operating point and exact interface match provide the basis for stable cooling and dependable replacement planning.

Application Industry

Frequently Asked Questions

What maximum airflow is listed for AFB0412HHB?

The workbook lists a maximum airflow of 19.3 m3/h. This is not the airflow at every system resistance; use the applicable pressure-flow curve to identify the installed operating point.

Does AFB0412HHB support speed control?

The filter data does not confirm a control interface. Check the exact-model datasheet and wiring for PWM, analog control, FG/RD feedback or fixed-speed operation before connection.

What equipment is AFB0412HHB intended to cool?

AFB0412HHB is listed for Server and Power Supply cooling. Confirm the installed airflow demand, pressure loss and ambient conditions before approval.

What supply voltage should be used for AFB0412HHB?

12VDC is listed for AFB0412HHB. Verify the allowable input range, phase, frequency where applicable, polarity and wiring diagram in the exact specification.

How should the pressure capability of AFB0412HHB be checked?

The workbook lists 89.4 Pa maximum pressure. Maximum pressure and maximum airflow occur at different points, so select AFB0412HHB from its curve at the required system resistance.

Can AFB0412HHB reduce total ownership cost?

The provided parameters do not prove a cost saving. Compare purchase price, power at the real operating point, service access, expected life and downtime risk for the complete cooling system.