A 75.51 Pa maximum static-pressure rating characterizes AFB0524VHD. Intended for server or power-supply cooling, the 24VDC axial fan uses a 50 x 50 x 20 mm body and is specified to run at 7000 rpm.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 50x50x20 |
| Max.Air Flow(m³/h) | 34.5 |
| Max.Pressure(Pa) | 75.51 |
| Input Power(W) | 2.4 |
| Speed(rpm) | 7000 |
| Noise(db) | 40.5 |
The Delta AFB0524VHD is a brushless DC axial fan for server and storage equipment. It provides a defined airflow path where equipment layout leaves limited room for passive heat removal.
Its listed 50x50x20 mm format defines the space needed for installation, helping designers reserve room for adjacent components and cable routing. The axial layout moves air along the fan axis, supporting a direct ventilation route through the equipment opening. Keeping inlet obstructions clear helps preserve useful airflow without spending extra power on avoidable system losses.
For OEM design-in and replacement sourcing, confirm the full suffix, connector and mounting pattern to support dependable service in the intended assembly.
Delta AFB0524VHD serves server and storage equipment, helping remove heat from processors, drives and other heat-producing assemblies. Airflow supports stable equipment temperatures.
In power-supply equipment, Delta AFB0524VHD helps remove heat from power-conversion components. The cooling solution addresses electrical conversion losses to support dependable power delivery.
For telecommunications equipment, Delta AFB0524VHD provides equipment cooling around densely arranged electronic assemblies. Managing continuous communication duty helps maintain service continuity.
In industrial control equipment, air movement helps handle heat accumulated within enclosures. Delta AFB0524VHD supports cooling around controllers and electronic modules, contributing to stable automation operation.
Isolate power first. Verify the approved supply, connector, polarity or phase, control-enable input and any obstruction; follow the exact specification and do not bypass protection circuits.
Serviceability depends on access, connector choice and mounting. Plan isolation and cleaning access, inspect the airflow path, and use the manufacturer's replacement guidance rather than attempting an unsupported repair.
The listed input-power figure is 2.4 W, but efficiency must be evaluated at the required airflow and pressure. Check the applicable fan curve and test conditions before comparison.
The workbook lists 75.51 Pa maximum pressure. Maximum pressure and maximum airflow occur at different points, so select AFB0524VHD from its curve at the required system resistance.
AFB0524VHD is listed for Server and Power Supply cooling. Confirm the installed airflow demand, pressure loss and ambient conditions before approval.

AFB0512VHD provides 12VDC axial fan cooling for power-supply electronics in a 50 mm frame. Its listed 1.92 W input distinguishes it from the 24VDC version; both the 20 mm depth and connector must suit the enclosure.
Read More
For server electronics, AFB0424VHD combines a 40 mm axial footprint with a 20 mm depth. This 24VDC fan lists 103.6 Pa maximum pressure and 9000 rpm operation, with 2.16 W input defining its electrical load.
Read More
A 1.44 W input makes AFB0624MB a lower-input entry among the listed 24VDC axial fan fans. For server and power-supply ventilation, it provides a 60 x 60 x 15 mm format with a specified 4000 rpm rotor.