GTB031FUC20R N1 is a nominal 230VAC EC centrifugal fan for server cooling. RS485 control and voltage/current monitoring are documented in its PDF, alongside 3014 m3/h maximum airflow and a 2500 rpm speed.
| Rated Voltage(V) | 1~230 |
|---|---|
| Size(mm) | 310 |
| Max.Air Flow(m³/h) | 3014 |
| Max.Pressure(Pa) | 74 |
| Input Power(W) | 530 |
| Speed(rpm) | 2500 |
| Noise(db) | 74.5 |
For precision cooling equipment, the GTB031FUC20R N1 from Delta is an EC centrifugal fan that supports active thermal management. A planned inlet-to-outlet route helps the installation carry component heat away.
The 1~230 V AC supply requirement gives electrical designers a clear basis for matching the fan to the equipment power architecture. Electronic commutation is part of the EC motor architecture; speed-control inputs must be checked against the complete electrical specification. Matching the fan curve to the finished air path supports efficient cooling; free-air flow alone does not determine installed performance.
Choose it for a model-specific cooling requirement, with connector, operating conditions and airflow direction checked before release to production.
For precision cooling equipment, Delta GTB031FUC20R N1 provides equipment cooling around heat-exchange sections. Managing continuous temperature-control demand helps maintain stable environmental conditions.
Delta GTB031FUC20R N1 serves server and storage equipment, helping remove heat from processors, drives and other heat-producing assemblies. Airflow supports stable equipment temperatures.
Delta GTB031FUC20R N1 supports cooling in telecommunications equipment. Air circulation around densely arranged electronic assemblies helps manage continuous communication duty, supporting service continuity.
The workbook lists a maximum airflow of 3014 m3/h. This is not the airflow at every system resistance; use the applicable pressure-flow curve to identify the installed operating point.
The listed noise value is 74.5 dB, but compare values only under matching test conditions. Installed noise also depends on speed, restriction, resonance and enclosure geometry.
The workbook lists 74 Pa maximum pressure. Maximum pressure and maximum airflow occur at different points, so select GTB031FUC20R N1 from its curve at the required system resistance.
GTB031FUC20R N1 is listed for Server cooling. Confirm the installed airflow demand, pressure loss and ambient conditions before approval.
The filter data does not confirm a control interface. Check the exact-model datasheet and wiring for PWM, analog control, FG/RD feedback or fixed-speed operation before connection.

With 1260 m3/h maximum airflow, GTB023EUG10R-V E1 serves server cooling as a nominal 230VAC EC centrifugal fan. Its PDF documents soft start and locked-rotor protection, plus 0-10V/PWM speed control.
Read More
GTB040PUD26R-M002 is a 400VAC EC centrifugal fan for server ventilation. Its supplied 404 mm diameter and 256.6 mm depth accompany a 1850 rpm speed, with 6004.4 m3/h maximum airflow listed.
Read More
For server cooling, GTB023EUG10R-VE1 combines nominal 230VAC EC centrifugal fan operation with 0-10V/PWM speed control. The PDF specifies 135 W at free air and 180 W at maximum load, clarifying its power profile.
Read More
GTB050PUT33R E1 pairs a 500 mm centrifugal fan format with EC drive for server ventilation. The 400VAC model lists 12286 m3/h maximum airflow and 1145 Pa maximum pressure, with 3100 W input specified.
Read More
GTB036PCN25R-M E1 is an EC centrifugal fan for server cooling, rated at three-phase 230/400VAC. Its PDF documents 0-10V, PWM and 4-20mA inputs plus RS485 Modbus, providing several control-interface choices.
Read More
GTB036PUD25E N1 is a 400VAC EC centrifugal fan for server cooling. A listed 919 Pa maximum pressure complements its 360 x 250 mm envelope and 2200 rpm rating, supporting comparison of ducted cooling designs.
Read More