GTB050PUT33R E1 pairs a 500 mm centrifugal fan format with EC drive for server ventilation. The 400VAC model lists 12286 m3/h maximum airflow and 1145 Pa maximum pressure, with 3100 W input specified.
| Rated Voltage(V) | 400 |
|---|---|
| Size(mm) | 500 |
| Max.Air Flow(m³/h) | 12286 |
| Max.Pressure(Pa) | 1145 |
| Input Power(W) | 3100 |
Equipment manufacturers evaluating server and storage equipment can consider Delta GTB050PUT33R E1, an EC centrifugal fan. The fan supports heat removal by keeping air moving through the selected cooling path.
The listed 3100 W power rating is relevant to supply sizing and the system energy budget; actual consumption depends on the operating duty. Electronic commutation is part of the EC motor architecture; speed-control inputs must be checked against the complete electrical specification. Separating the intake from warmed exhaust improves the effectiveness of air exchange across the equipment section.
This fan is a practical candidate for equipment builders and service teams when its verified duty point and mounting interface match the finished system.
In precision cooling equipment, Delta GTB050PUT33R E1 helps remove heat from heat-exchange sections. The cooling solution addresses continuous temperature-control demand to support stable environmental conditions.
Delta GTB050PUT33R E1 serves server and storage equipment, helping remove heat from processors, drives and other heat-producing assemblies. Airflow supports stable equipment temperatures.
In telecommunications equipment, air movement helps handle continuous communication duty. Delta GTB050PUT33R E1 supports cooling around densely arranged electronic assemblies, contributing to service continuity.
A matching outline alone does not prove compatibility. Check 400VAC, mounting dimensions, connector, pinout, airflow direction, control signals and the required pressure-flow point.
3100 W is shown in the filter data. Check whether the corresponding datasheet defines it as rated, free-air or maximum-load input before sizing the power source.
No speed value is present in the filter row. Confirm rated speed and any control range from the exact-model specification before selection.
Use the exact-model acoustic data, but compare values only under matching test conditions. Installed noise also depends on speed, restriction, resonance and enclosure geometry.
GTB050PUT33R E1 is listed for Server cooling. Confirm the installed airflow demand, pressure loss and ambient conditions before approval.

With 1260 m3/h maximum airflow, GTB023EUG10R-V E1 serves server cooling as a nominal 230VAC EC centrifugal fan. Its PDF documents soft start and locked-rotor protection, plus 0-10V/PWM speed control.
Read More
GTB040PUD26R-M002 is a 400VAC EC centrifugal fan for server ventilation. Its supplied 404 mm diameter and 256.6 mm depth accompany a 1850 rpm speed, with 6004.4 m3/h maximum airflow listed.
Read More
For server cooling, GTB023EUG10R-VE1 combines nominal 230VAC EC centrifugal fan operation with 0-10V/PWM speed control. The PDF specifies 135 W at free air and 180 W at maximum load, clarifying its power profile.
Read More
GTB031FUC20R N1 is a nominal 230VAC EC centrifugal fan for server cooling. RS485 control and voltage/current monitoring are documented in its PDF, alongside 3014 m3/h maximum airflow and a 2500 rpm speed.
Read More
GTB036PCN25R-M E1 is an EC centrifugal fan for server cooling, rated at three-phase 230/400VAC. Its PDF documents 0-10V, PWM and 4-20mA inputs plus RS485 Modbus, providing several control-interface choices.
Read More
GTB036PUD25E N1 is a 400VAC EC centrifugal fan for server cooling. A listed 919 Pa maximum pressure complements its 360 x 250 mm envelope and 2200 rpm rating, supporting comparison of ducted cooling designs.
Read More