For server cooling, GTB063PUU38R-VHR3 offers an EC centrifugal fan format with a listed 630 mm size. The supplied input range is three-phase 380-480VAC, with 20381 m3/h maximum airflow and 1807 Pa maximum pressure.
| Rated Voltage(V) | 3~380-480 |
|---|---|
| Size(mm) | 630 |
| Max.Air Flow(m³/h) | 20381 |
| Max.Pressure(Pa) | 1807 |
| Input Power(W) | 3700 |
Designed for server and storage equipment, Delta GTB063PUU38R-VHR3 brings EC centrifugal fan integration to thermally loaded assemblies. Its role is to move cooling air across components during equipment operation.
The 3~380-480 V AC supply requirement gives electrical designers a clear basis for matching the fan to the equipment power architecture. Electronic commutation is part of the EC motor architecture; speed-control inputs must be checked against the complete electrical specification. Good inlet spacing helps reduce turbulence, which matters when balancing usable cooling capacity against installed sound levels.
Equipment manufacturers and maintenance teams should match the complete part number and installation limits for reliable operation across the service cycle.
For precision cooling equipment, Delta GTB063PUU38R-VHR3 provides equipment cooling around heat-exchange sections. Managing continuous temperature-control demand helps maintain stable environmental conditions.
Delta GTB063PUU38R-VHR3 serves server and storage equipment, helping remove heat from processors, drives and other heat-producing assemblies. Airflow supports stable equipment temperatures.
Delta GTB063PUU38R-VHR3 supports cooling in telecommunications equipment. Air circulation around densely arranged electronic assemblies helps manage continuous communication duty, supporting service continuity.
A matching outline alone does not prove compatibility. Check 3~380-480VAC, mounting dimensions, connector, pinout, airflow direction, control signals and the required pressure-flow point.
GTB063PUU38R-VHR3 is listed for Server cooling. Confirm the installed airflow demand, pressure loss and ambient conditions before approval.
The provided parameters do not prove a cost saving. Compare purchase price, power at the real operating point, service access, expected life and downtime risk for the complete cooling system.
3~380-480VAC is listed for GTB063PUU38R-VHR3. Verify the allowable input range, phase, frequency where applicable, polarity and wiring diagram in the exact specification.
The filter data does not confirm a control interface. Check the exact-model datasheet and wiring for PWM, analog control, FG/RD feedback or fixed-speed operation before connection.

With 1260 m3/h maximum airflow, GTB023EUG10R-V E1 serves server cooling as a nominal 230VAC EC centrifugal fan. Its PDF documents soft start and locked-rotor protection, plus 0-10V/PWM speed control.
Read More
GTB040PUD26R-M002 is a 400VAC EC centrifugal fan for server ventilation. Its supplied 404 mm diameter and 256.6 mm depth accompany a 1850 rpm speed, with 6004.4 m3/h maximum airflow listed.
Read More
For server cooling, GTB023EUG10R-VE1 combines nominal 230VAC EC centrifugal fan operation with 0-10V/PWM speed control. The PDF specifies 135 W at free air and 180 W at maximum load, clarifying its power profile.
Read More
GTB031FUC20R N1 is a nominal 230VAC EC centrifugal fan for server cooling. RS485 control and voltage/current monitoring are documented in its PDF, alongside 3014 m3/h maximum airflow and a 2500 rpm speed.
Read More
GTB050PUT33R E1 pairs a 500 mm centrifugal fan format with EC drive for server ventilation. The 400VAC model lists 12286 m3/h maximum airflow and 1145 Pa maximum pressure, with 3100 W input specified.
Read More
GTB036PCN25R-M E1 is an EC centrifugal fan for server cooling, rated at three-phase 230/400VAC. Its PDF documents 0-10V, PWM and 4-20mA inputs plus RS485 Modbus, providing several control-interface choices.
Read More