Within servers and data-center electronics, SUNON PF36281BX-0000-A99 serves as a 36 × 36 × 28 mm DC axial fan operating at 12 VDC. 635.2 Pa maximum pressure is the standout documented duty-point value. Treat the sound level as a primary input to design qualification. Match the exact part number before approving a substitute.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 36x36x28mm |
| Max.Air Flow(m³/h) | 38.7 |
| Max.Pressure(Pa) | 635.2 |
| Speed(rpm) | 3000 |
| Noise(db) | 61.9 |
SUNON PF36281BX-0000-A99 supports server and data-center equipment with DC brushless axial fan airflow. It is intended for installations where predictable air exchange is central to equipment stability.
The brushless DC motor architecture supports efficient electronic commutation and stable rotational performance for compact equipment cooling. Correct airflow direction and inlet clearance help translate the documented operating point into reliable equipment-level cooling.
For PF36281BX-0000-A99 integration, prioritize inlet clearance. Include prototype trials in engineering approval, and confirm the full model interface during sourcing review. This supports reliable cooling and traceable purchasing. Use a representative assembly rather than an unrestricted bench setup.
SUNON PF36281BX-0000-A99 serves server platforms. Airflow around processors, memory and power components helps address sustained computing loads. The fan gives OEM equipment a defined air route and supports stable server operation. It supports reliable equipment cooling.
SUNON PF36281BX-0000-A99 serves storage equipment. Airflow around drives, controllers and power assemblies helps address continuous data workloads. The fan gives OEM equipment a defined air route and supports reliable storage availability. It supports reliable equipment cooling.
SUNON PF36281BX-0000-A99 serves edge-computing systems. Airflow around compact processing and communication modules helps address high heat density. The fan gives OEM equipment a defined air route and supports consistent thermal control. It supports reliable equipment cooling.
SUNON PF36281BX-0000-A99 serves data-center equipment. Airflow around critical computing assemblies helps address round-the-clock heat generation. The fan gives OEM equipment a defined air route and supports infrastructure availability. It supports reliable equipment cooling.
The worksheet lists up to 38.7 m³/h. Verify the operating point against system resistance.
The exact bearing option is not confirmed by the row-level data. Check the complete suffix in the current SUNON specification.
Use the listed voltage, size, 38.7 m³/h airflow, 3000 rpm for preliminary comparison.
The workbook marks the product as RoHS compliant. Confirm UL, TUV, VDE, or other project-specific approvals for the exact suffix.
Confirm any missing bearing, connector, control, IP rating, life, certification, and performance-curve details for the complete part number.
Inspect for dust, blocked airflow, abnormal noise, loose mounting, and wiring damage. Isolate power before cleaning or service.

Within servers and data-center electronics, SUNON PF60252B3-10000-A99 serves as a 60 × 60 × 25 mm DC axial fan operating at 24 VDC. 102.1 Pa maximum pressure is the standout documented duty-point value. For installation review, start with the supplied electrical load. Obtain the applicable curve before final duty-point approval.
Read More
For servers and data-center electronics, PF60252B2-10000-A99 combines 24 VDC operation with a 60 × 60 × 25 mm DC axial fan design. 124.5 Pa maximum pressure is the standout documented duty-point value. Use the documented speed benchmark when planning installation review. Obtain the applicable curve before final duty-point approval.
Read More
The PF60252B1-10000-A99 is SUNON's 24 VDC, 60 × 60 × 25 mm DC axial fan option for servers and data-center electronics. 139.5 Pa maximum pressure is the standout documented duty-point value. Review its airflow profile during installation review. Obtain the applicable curve before final duty-point approval.
Read More
For ventilation needs in servers and data-center electronics, the PF60251VX-10000-A99 provides a 12 VDC DC axial fan configuration measuring 60 × 60 × 25 mm. 8300 rpm is the model's most distinctive operating parameter. Treat the application data as a primary input to design qualification. Match the exact part number before approving a substitute.
Read More
SUNON PF60251V3-10000-A99 combines a 60 × 60 × 25 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. 102.1 Pa maximum pressure is the standout documented duty-point value. Base design qualification on the stated technical profile. Match the exact part number before approving a substitute.
Read More
Configured for servers and data-center electronics, SUNON PF60251V2-10000-A99 is a 12 VDC DC axial fan in a 60 × 60 × 25 mm frame. 124.5 Pa maximum pressure is the standout documented duty-point value. During design qualification, compare the model's model record. Match the exact part number before approving a substitute.
Read More