Within servers and data-center electronics, SUNON PF75301B3-1B000-A99 serves as a 75 × 75 × 30 mm DC blower operating at 12 VDC. Its 2400 rpm rating defines a lower-speed operating point. Treat the equipment fit as a primary input to installation review. Obtain the applicable curve before final duty-point approval.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 75x75x30mm |
| Max.Air Flow(m³/h) | 18.3 |
| Max.Pressure(Pa) | 59.8 |
| Input Power(W) | 0.99 |
| Speed(rpm) | 2400 |
| Noise(db) | 32.9 |
Designed for server and data-center equipment, the SUNON PF75301B3-1B000-A99 provides DC brushless blower cooling in a format suited to equipment integration. It helps limit local heat buildup during operation.
The brushless DC motor architecture supports efficient electronic commutation and stable rotational performance for compact equipment cooling. System resistance, grille geometry and cable clearance should be reviewed together to maintain predictable air delivery.
Design approval for PF75301B3-1B000-A99 should cover cable routing together with system-resistance review during sourcing review. This creates a practical link between thermal validation, purchasing documentation and future servicing. Include filters, vents and grilles when checking available airflow.
SUNON PF75301B3-1B000-A99 serves server platforms. Airflow around processors, memory and power components helps address sustained computing loads. The fan gives OEM equipment a defined air route and supports stable server operation. It supports reliable equipment cooling.
SUNON PF75301B3-1B000-A99 serves storage equipment. Airflow around drives, controllers and power assemblies helps address continuous data workloads. The fan gives OEM equipment a defined air route and supports reliable storage availability. It supports reliable equipment cooling.
SUNON PF75301B3-1B000-A99 serves edge-computing systems. Airflow around compact processing and communication modules helps address high heat density. The fan gives OEM equipment a defined air route and supports consistent thermal control. It supports reliable equipment cooling.
SUNON PF75301B3-1B000-A99 serves data-center equipment. Airflow around critical computing assemblies helps address round-the-clock heat generation. The fan gives OEM equipment a defined air route and supports infrastructure availability. It supports reliable equipment cooling.
The supplied row does not state the connector or lead configuration. Follow the model-specific wiring drawing.
Inspect for dust, blocked airflow, abnormal noise, loose mounting, and wiring damage. Isolate power before cleaning or service.
Its documented 12 VDC rating and its 2400 rpm rating defines a lower-speed operating point. allow comparison with the required duty point without assuming unlisted options.
The listed rating is 12 VDC. Verify polarity or mains frequency, wiring, and protection before commissioning.
The supplied product-line reference discusses long-life cooling, but continuous-duty limits for this full suffix must be verified from its datasheet and operating conditions.
The exact bearing option is not confirmed by the row-level data. Check the complete suffix in the current SUNON specification.