AFB0412MB is a 12VDC axial fan for power supplies and server electronics, specified at 6000 rpm. The 40 x 40 x 15 mm model lists a 1.08 W input, distinguishing it from faster 40 mm variants in the supplied set.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 40*40*15 |
| Max.Air Flow(m³/h) | 13.77 |
| Input Power(W) | 1.08 |
| Speed(rpm) | 6000 |
| Noise(db) | 24.5 |
Equipment manufacturers evaluating telecommunications equipment can consider Delta AFB0412MB, a brushless DC axial fan. The fan supports heat removal by keeping air moving through the selected cooling path.
The listed 1.08 W input is relevant to supply sizing and the system energy budget; actual consumption depends on the operating duty. The series combines ball-bearing construction with UL 94V-0 materials, addressing mechanical durability and component flammability requirements. Good inlet spacing helps reduce turbulence, which matters when balancing usable cooling capacity against installed sound levels.
For system integrators, a confirmed operating point and exact interface match provide the basis for stable cooling and dependable replacement planning.
Delta AFB0412MB serves server and storage equipment, helping remove heat from processors, drives and other heat-producing assemblies. Airflow supports stable equipment temperatures.
Delta AFB0412MB supports cooling in power-supply equipment. Air circulation around power-conversion components helps manage electrical conversion losses, supporting dependable power delivery.
In telecommunications equipment, Delta AFB0412MB helps remove heat from densely arranged electronic assemblies. The cooling solution addresses continuous communication duty to support service continuity.
For industrial control equipment, Delta AFB0412MB provides equipment cooling around controllers and electronic modules. Managing heat accumulated within enclosures helps maintain stable automation operation.
AFB0412MB is listed for Server and Power Supply cooling. Confirm the installed airflow demand, pressure loss and ambient conditions before approval.
6000 rpm is listed in the workbook. This value alone does not establish adjustable-speed capability; confirm the control input and permitted operating range in the exact datasheet.
Suitability depends on thermal margin, operating temperature, alarm or feedback requirements and system redundancy. Qualify AFB0412MB at the actual duty point; the model name alone is not a reliability guarantee.
The workbook lists a maximum airflow of 13.77 m3/h. This is not the airflow at every system resistance; use the applicable pressure-flow curve to identify the installed operating point.
In Stock is shown in the workbook, but this is not a delivery guarantee. Confirm the complete part number, quantity, current inventory and committed lead time when ordering.
Isolate power first. Verify the approved supply, connector, polarity or phase, control-enable input and any obstruction; follow the exact specification and do not bypass protection circuits.

A 1.44 W input makes AFB0624MB a lower-input entry among the listed 24VDC axial fan fans. For server and power-supply ventilation, it provides a 60 x 60 x 15 mm format with a specified 4000 rpm rotor.
Read More
The 210.2 Pa maximum-pressure entry is a key reason to evaluate AFB1224EHE-C for power-supply ventilation. This 24VDC axial fan occupies a 120 x 120 x 38 mm space; final selection still depends on the duty point.
Read More
AFB0612HH-A combines a 5000 rpm rotor with a 12VDC axial fan motor for server and power-supply cooling. Its listed 2.04 W input and 74 Pa maximum static pressure accompany a 60 x 60 x 25.4 mm frame.
Read More
AFB1224GHE-C is a 24VDC axial fan for server chassis, with 409.7 m3/h listed maximum airflow. Its 27.6 W input differs from the 12VDC GHE entry; retain the -C suffix when checking connector and control configuration.
Read More
AFB0912HH supports storage-enclosure cooling with a 12VDC axial fan design. At 3200 rpm and 3 W listed input, it represents a distinct operating choice among the supplied 92 mm fans, with a specified 25.4 mm depth.
Read More
Server chassis with space for a 38 mm-deep fan can consider AFB0824SHE, an 80 mm axial model powered by 24VDC. Its listed airflow ceiling is 123.6 m3/h, a useful comparison point for enclosure ventilation designs.
Read More