Server chassis with space for a 38 mm-deep fan can consider AFB0824SHE, an 80 mm axial model powered by 24VDC. Its listed airflow ceiling is 123.6 m3/h, a useful comparison point for enclosure ventilation designs.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 80×80×38.00 |
| Max.Air Flow(m³/h) | 123.6 |
| Max.Pressure(Pa) | 136.2 |
| Input Power(W) | 8.4 |
| Speed(rpm) | 5000 |
| Noise(db) | 46 |
AFB0824SHE is a Delta cooling solution for server and storage equipment. This brushless DC axial fan gives designers a practical means of circulating air through a thermally loaded equipment section.
A listed speed of 5000 rpm helps define the operating profile when reviewing airflow demand, mechanical mounting and the enclosure's acoustic target. The axial layout moves air along the fan axis, supporting a direct ventilation route through the equipment opening. Good inlet spacing helps reduce turbulence, which matters when balancing usable cooling capacity against installed sound levels.
Choose it for a model-specific cooling requirement, with connector, operating conditions and airflow direction checked before release to production.
Delta AFB0824SHE serves server and storage equipment, helping remove heat from processors, drives and other heat-producing assemblies. Airflow supports stable equipment temperatures.
For power-supply equipment, Delta AFB0824SHE provides equipment cooling around power-conversion components. Managing electrical conversion losses helps maintain dependable power delivery.
In telecommunications equipment, air movement helps handle continuous communication duty. Delta AFB0824SHE supports cooling around densely arranged electronic assemblies, contributing to service continuity.
Delta AFB0824SHE supports cooling in industrial control equipment. Air circulation around controllers and electronic modules helps manage heat accumulated within enclosures, supporting stable automation operation.
The workbook lists 80 x 80 x 38.00 mm. Confirm overall depth, hole pattern, connector clearance and guard or inlet-ring dimensions in the exact mechanical drawing.
Allow for the listed 80 x 80 x 38.00 mm size and follow the exact mounting drawing. Keep inlet and outlet clear, use the specified fasteners and verify wiring before energizing the fan.
8.4 W is shown in the filter data. Check whether the corresponding datasheet defines it as rated, free-air or maximum-load input before sizing the power source.
5000 rpm is listed in the workbook. This value alone does not establish adjustable-speed capability; confirm the control input and permitted operating range in the exact datasheet.
AFB0824SHE is listed for Server and Power Supply cooling. Confirm the installed airflow demand, pressure loss and ambient conditions before approval.

The 210.2 Pa maximum-pressure entry is a key reason to evaluate AFB1224EHE-C for power-supply ventilation. This 24VDC axial fan occupies a 120 x 120 x 38 mm space; final selection still depends on the duty point.
Read More
A 1.44 W input makes AFB0624MB a lower-input entry among the listed 24VDC axial fan fans. For server and power-supply ventilation, it provides a 60 x 60 x 15 mm format with a specified 4000 rpm rotor.
Read More
AFB0612HH-A combines a 5000 rpm rotor with a 12VDC axial fan motor for server and power-supply cooling. Its listed 2.04 W input and 74 Pa maximum static pressure accompany a 60 x 60 x 25.4 mm frame.
Read More
AFB1224GHE-C is a 24VDC axial fan for server chassis, with 409.7 m3/h listed maximum airflow. Its 27.6 W input differs from the 12VDC GHE entry; retain the -C suffix when checking connector and control configuration.
Read More
AFB0912HH supports storage-enclosure cooling with a 12VDC axial fan design. At 3200 rpm and 3 W listed input, it represents a distinct operating choice among the supplied 92 mm fans, with a specified 25.4 mm depth.
Read More
A deeper 70 x 70 x 38 mm frame distinguishes AFB0712VHE for server and power-supply cooling. The 12VDC axial fan lists 7000 rpm operation and 216.7 Pa maximum pressure, with an 8.4 W input rating.
Read More