Get Quote
Home > Products > By type > Compact Fans > AFB0412SHB | Delta Electronics 12VDC 3W Axial Fan for Server, Storage and Power Supply Cooling

AFB0412SHB Delta Compact Fan

Brand :
Delta
Model:
AFB0412SHB | Delta Electronics 12VDC 3W Axial Fan for Server, Storage and Power Supply Cooling
Type:
Compact Fans
Industry:
Data Center Cooling
Description:

The AFB0412SHB uses a 12VDC axial fan design in a 40 x 40 x 15 mm frame for server and storage cooling. Its 11000 rpm rotor and 3 W listed input define a high-speed option within this compact size class.

Datasheet:
AFB0412SHB | Delta Electronics 12VDC 3W Axial Fan for Server, Storage and Power Supply Cooling Datasheet (Pdf)

Product Features

Rated Voltage(V)12
Size(mm)40*40*15
Max.Air Flow(m³/h)8.7
Max.Pressure(Pa)16
Input Power(W)3
Speed(rpm)11000
Noise(db)41.5

Product Features

Compact DC Cooling

In power-supply equipment, Delta AFB0412SHB supplies the forced-air element of the cooling system. As a brushless DC axial fan, it is intended for integration into a defined mechanical and electrical assembly.

The listed 3 W input is relevant to supply sizing and the system energy budget; actual consumption depends on the operating duty. The series combines ball-bearing construction with UL 94V-0 materials, addressing mechanical durability and component flammability requirements. Selecting the operating point against real pressure loss helps avoid oversizing and keeps thermal design focused on useful air delivery.

For procurement, retain the complete model code and check the interface against the drawing; this supports repeatable assembly and accurate replacement ordering.

Application Industry

Frequently Asked Questions

What equipment is AFB0412SHB intended to cool?

AFB0412SHB is listed for Server, Storage and Power Supply cooling. Confirm the installed airflow demand, pressure loss and ambient conditions before approval.

What installation space is required for AFB0412SHB?

The workbook lists 40 x 40 x 15 mm. Confirm overall depth, hole pattern, connector clearance and guard or inlet-ring dimensions in the exact mechanical drawing.

What should be checked if AFB0412SHB fails to start?

Isolate power first. Verify the approved supply, connector, polarity or phase, control-enable input and any obstruction; follow the exact specification and do not bypass protection circuits.

What should be checked when installing AFB0412SHB?

Allow for the listed 40 x 40 x 15 mm size and follow the exact mounting drawing. Keep inlet and outlet clear, use the specified fasteners and verify wiring before energizing the fan.

Which certifications or standards apply to AFB0412SHB?

RoHS Compliant is listed in the workbook. Obtain the current exact-model declaration and datasheet before claiming safety approvals, ingress protection or international compliance.

Message Form