The 40 x 40 x 15 mm AFB0424VHB is a 24VDC axial fan for server and power-supply cooling. Its listed 9500 rpm speed and 114.3 Pa maximum static pressure define this compact model's selection profile.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 40*40*15 |
| Max.Air Flow(m³/h) | 22.1 |
| Max.Pressure(Pa) | 114.3 |
| Input Power(W) | 2.4 |
| Speed(rpm) | 9500 |
| Noise(db) | 36.5 |
The AFB0424VHB addresses ventilation needs in industrial control equipment. Delta's brushless DC axial fan format allows cooling airflow to be integrated alongside the equipment's heat-producing assemblies.
A listed speed of 9500 rpm helps define the operating profile when reviewing airflow demand, mechanical mounting and the enclosure's acoustic target. The axial layout moves air along the fan axis, supporting a direct ventilation route through the equipment opening. A controlled exhaust route limits recirculation, allowing the delivered air to carry heat away rather than return to the inlet.
OEM purchasers can specify this model after checking the thermal duty, supply and mechanical fit, keeping reliable equipment operation central to selection.
Delta AFB0424VHB serves server and storage equipment, helping remove heat from processors, drives and other heat-producing assemblies. Airflow supports stable equipment temperatures.
Delta AFB0424VHB supports cooling in power-supply equipment. Air circulation around power-conversion components helps manage electrical conversion losses, supporting dependable power delivery.
In telecommunications equipment, Delta AFB0424VHB helps remove heat from densely arranged electronic assemblies. The cooling solution addresses continuous communication duty to support service continuity.
For industrial control equipment, Delta AFB0424VHB provides equipment cooling around controllers and electronic modules. Managing heat accumulated within enclosures helps maintain stable automation operation.
24VDC is listed for AFB0424VHB. Verify the allowable input range, phase, frequency where applicable, polarity and wiring diagram in the exact specification.
Isolate power first. Verify the approved supply, connector, polarity or phase, control-enable input and any obstruction; follow the exact specification and do not bypass protection circuits.
Suitability depends on thermal margin, operating temperature, alarm or feedback requirements and system redundancy. Qualify AFB0424VHB at the actual duty point; the model name alone is not a reliability guarantee.
The workbook lists 40 x 40 x 15 mm. Confirm overall depth, hole pattern, connector clearance and guard or inlet-ring dimensions in the exact mechanical drawing.
In Stock is shown in the workbook, but this is not a delivery guarantee. Confirm the complete part number, quantity, current inventory and committed lead time when ordering.
AFB0424VHB is listed for Server and Power Supply cooling. Confirm the installed airflow demand, pressure loss and ambient conditions before approval.

The 210.2 Pa maximum-pressure entry is a key reason to evaluate AFB1224EHE-C for power-supply ventilation. This 24VDC axial fan occupies a 120 x 120 x 38 mm space; final selection still depends on the duty point.
Read More
A 1.44 W input makes AFB0624MB a lower-input entry among the listed 24VDC axial fan fans. For server and power-supply ventilation, it provides a 60 x 60 x 15 mm format with a specified 4000 rpm rotor.
Read More
AFB0612HH-A combines a 5000 rpm rotor with a 12VDC axial fan motor for server and power-supply cooling. Its listed 2.04 W input and 74 Pa maximum static pressure accompany a 60 x 60 x 25.4 mm frame.
Read More
AFB1224GHE-C is a 24VDC axial fan for server chassis, with 409.7 m3/h listed maximum airflow. Its 27.6 W input differs from the 12VDC GHE entry; retain the -C suffix when checking connector and control configuration.
Read More
AFB0912HH supports storage-enclosure cooling with a 12VDC axial fan design. At 3200 rpm and 3 W listed input, it represents a distinct operating choice among the supplied 92 mm fans, with a specified 25.4 mm depth.
Read More
Server chassis with space for a 38 mm-deep fan can consider AFB0824SHE, an 80 mm axial model powered by 24VDC. Its listed airflow ceiling is 123.6 m3/h, a useful comparison point for enclosure ventilation designs.
Read More