A listed 3500 rpm speed and 6.48 W input identify AFB1224HHE for server and power-supply cooling. This 24VDC axial fan has a 120 x 120 x 38 mm frame, providing a specific fit for 38 mm-deep installations.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 120*120*38 |
| Max.Air Flow(m³/h) | 222 |
| Max.Pressure(Pa) | 9 |
| Input Power(W) | 6.48 |
| Speed(rpm) | 3500 |
| Noise(db) | 47 |
For industrial control equipment, the AFB1224HHE from Delta is a brushless DC axial fan that supports active thermal management. A planned inlet-to-outlet route helps the installation carry component heat away.
Its listed 120 x 120 x 38 mm format defines the space needed for installation, helping designers reserve room for adjacent components and cable routing. The series uses ball-bearing motor support for rotational durability, giving OEMs a service-life-oriented construction for equipment cooling. A controlled exhaust route limits recirculation, allowing the delivered air to carry heat away rather than return to the inlet.
It suits engineering buyers who need a defined cooling component. Verify the exact wiring and environmental limits before approving long-term installation.
Delta AFB1224HHE serves server and storage equipment, helping remove heat from processors, drives and other heat-producing assemblies. Airflow supports stable equipment temperatures.
For power-supply equipment, Delta AFB1224HHE provides equipment cooling around power-conversion components. Managing electrical conversion losses helps maintain dependable power delivery.
In telecommunications equipment, air movement helps handle continuous communication duty. Delta AFB1224HHE supports cooling around densely arranged electronic assemblies, contributing to service continuity.
Delta AFB1224HHE supports cooling in industrial control equipment. Air circulation around controllers and electronic modules helps manage heat accumulated within enclosures, supporting stable automation operation.
The workbook lists a maximum airflow of 222 m3/h. This is not the airflow at every system resistance; use the applicable pressure-flow curve to identify the installed operating point.
AFB1224HHE is listed for Server and Power Supply cooling. Confirm the installed airflow demand, pressure loss and ambient conditions before approval.
The listed input-power figure is 6.48 W, but efficiency must be evaluated at the required airflow and pressure. Check the applicable fan curve and test conditions before comparison.
Serviceability depends on access, connector choice and mounting. Plan isolation and cleaning access, inspect the airflow path, and use the manufacturer's replacement guidance rather than attempting an unsupported repair.
A matching outline alone does not prove compatibility. Check 24VDC, mounting dimensions, connector, pinout, airflow direction, control signals and the required pressure-flow point.

The 210.2 Pa maximum-pressure entry is a key reason to evaluate AFB1224EHE-C for power-supply ventilation. This 24VDC axial fan occupies a 120 x 120 x 38 mm space; final selection still depends on the duty point.
Read More
A 1.44 W input makes AFB0624MB a lower-input entry among the listed 24VDC axial fan fans. For server and power-supply ventilation, it provides a 60 x 60 x 15 mm format with a specified 4000 rpm rotor.
Read More
AFB0612HH-A combines a 5000 rpm rotor with a 12VDC axial fan motor for server and power-supply cooling. Its listed 2.04 W input and 74 Pa maximum static pressure accompany a 60 x 60 x 25.4 mm frame.
Read More
AFB1224GHE-C is a 24VDC axial fan for server chassis, with 409.7 m3/h listed maximum airflow. Its 27.6 W input differs from the 12VDC GHE entry; retain the -C suffix when checking connector and control configuration.
Read More
AFB0912HH supports storage-enclosure cooling with a 12VDC axial fan design. At 3200 rpm and 3 W listed input, it represents a distinct operating choice among the supplied 92 mm fans, with a specified 25.4 mm depth.
Read More
Server chassis with space for a 38 mm-deep fan can consider AFB0824SHE, an 80 mm axial model powered by 24VDC. Its listed airflow ceiling is 123.6 m3/h, a useful comparison point for enclosure ventilation designs.
Read More