Get Quote
Home > Products > By type > Axial Fans > GTW017EUB12 | Delta Electronics 1~200-240VAC 240W EC Axial Fan for Server and Precision Cooling

GTW017EUB12 Delta Axial Fan

Brand :
Delta
Model:
GTW017EUB12 | Delta Electronics 1~200-240VAC 240W EC Axial Fan for Server and Precision Cooling
Type:
Axial Fans
Industry:
Data Center Cooling
Description:

GTW017EUB12 is an EC axial fan for server and precision cooling with a specified 200-240VAC input. Its PDF documents 0-10V/PWM speed control and a fan-speed signal, alongside a 5800 rpm rating.

Datasheet:
GTW017EUB12 | Delta Electronics 1~200-240VAC 240W EC Axial Fan for Server and Precision Cooling Datasheet (Pdf)

Product Features

Rated Voltage(V)1~200-240
Size(mm)200 x 122
Max.Air Flow(m³/h)1177
Max.Pressure(Pa)844
Input Power(W)240
Speed(rpm)5800
Noise(db)70.5

Product Features

EC Axial Cooling

The GTW017EUB12 addresses ventilation needs in server and storage equipment. Delta's EC axial fan format allows cooling airflow to be integrated alongside the equipment's heat-producing assemblies.

The 1~200-240 V AC supply requirement gives electrical designers a clear basis for matching the fan to the equipment power architecture. Ball-bearing motor support provides a durable rotating assembly for repeated operating duty. Keeping inlet obstructions clear helps preserve useful airflow without spending extra power on avoidable system losses.

For system integrators, a confirmed operating point and exact interface match provide the basis for stable cooling and dependable replacement planning.

Application Industry

Frequently Asked Questions

What equipment is GTW017EUB12 intended to cool?

GTW017EUB12 is listed for Server and Precision cooling. Confirm the installed airflow demand, pressure loss and ambient conditions before approval.

What installation space is required for GTW017EUB12?

The workbook lists 200 x 122 mm. Confirm overall depth, hole pattern, connector clearance and guard or inlet-ring dimensions in the exact mechanical drawing.

What should be checked if GTW017EUB12 fails to start?

Isolate power first. Verify the approved supply, connector, polarity or phase, control-enable input and any obstruction; follow the exact specification and do not bypass protection circuits.

What operating speed is listed for GTW017EUB12?

5800 rpm is listed in the workbook. This value alone does not establish adjustable-speed capability; confirm the control input and permitted operating range in the exact datasheet.

Can GTW017EUB12 directly replace another fan?

A matching outline alone does not prove compatibility. Check 1~200-240VAC, mounting dimensions, connector, pinout, airflow direction, control signals and the required pressure-flow point.

How should noise from GTW017EUB12 be evaluated?

The listed noise value is 70.5 dB, but compare values only under matching test conditions. Installed noise also depends on speed, restriction, resonance and enclosure geometry.