GTW091PUU29E-V001 Delta Axial Fan

Brand :
Delta
Model:
GTW091PUU29E-V001 | Delta Electronics 400VAC 4000W EC Axial Fan for Server and Precision Cooling
Type:
Axial Fans
Industry:
Data Center Cooling
Description:

GTW091PUU29E-V001 uses nominal 400VAC EC axial fan drive for server and precision cooling. The supplied PDF documents IP55 protection, 0-10V/PWM control and a maximum airflow of 34410 m3/h at the rated setup.

Datasheet:
GTW091PUU29E-V001 | Delta Electronics 400VAC 4000W EC Axial Fan for Server and Precision Cooling Datasheet (Pdf)

Product Features

Rated Voltage(V)400
Size(mm)910
Max.Air Flow(m³/h)11906
Max.Pressure(Pa)364
Input Power(W)4000
Speed(rpm)1260
Noise(db)86.3

Product Features

EC Axial Cooling

Designed for server and storage equipment, Delta GTW091PUU29E-V001 brings EC axial fan integration to thermally loaded assemblies. Its role is to move cooling air across components during equipment operation.

A specified maximum airflow of 34410 m3/h provides air-delivery capacity for thermal design; the installed duty must also account for system resistance. The 0-10 V and PWM control inputs allow airflow demand to guide motor speed, supporting part-load energy and acoustic management. A controlled exhaust route limits recirculation, allowing the delivered air to carry heat away rather than return to the inlet.

It suits engineering buyers who need a defined cooling component. Verify the exact wiring and environmental limits before approving long-term installation.

Application Industry

Frequently Asked Questions

What supply voltage should be used for GTW091PUU29E-V001?

400VAC is listed for GTW091PUU29E-V001. Verify the allowable input range, phase, frequency where applicable, polarity and wiring diagram in the exact specification.

What power figure is listed for GTW091PUU29E-V001?

4000 W is shown in the filter data. Check whether the corresponding datasheet defines it as rated, free-air or maximum-load input before sizing the power source.

Can GTW091PUU29E-V001 reduce total ownership cost?

The provided parameters do not prove a cost saving. Compare purchase price, power at the real operating point, service access, expected life and downtime risk for the complete cooling system.

What installation space is required for GTW091PUU29E-V001?

The workbook lists 910 mm. Confirm overall depth, hole pattern, connector clearance and guard or inlet-ring dimensions in the exact mechanical drawing.

What equipment is GTW091PUU29E-V001 intended to cool?

GTW091PUU29E-V001 is listed for Server and Precision cooling. Confirm the installed airflow demand, pressure loss and ambient conditions before approval.