Home > Products > By type > Blower Fans > AFB0412HHA | Delta Electronics 12VDC 6W Axial Fan for Server, Storage and Power Supply Cooling

AFB0412HHA Delta Blower Fan

Brand :
Delta
Model:
AFB0412HHA | Delta Electronics 12VDC 6W Axial Fan for Server, Storage and Power Supply Cooling
Type:
Blower Fans
Industry:
Data Center Cooling
Description:

Server and storage enclosures with limited depth can use the AFB0412HHA format: 40 x 40 x 10 mm. This 12VDC axial fan is listed at 7000 rpm, making its shallow body a principal installation feature.

Datasheet:
AFB0412HHA | Delta Electronics 12VDC 6W Axial Fan for Server, Storage and Power Supply Cooling Datasheet (Pdf)

Product Features

Rated Voltage(V)12
Size(mm)40*40*10
Max.Air Flow(m³/h)13.855
Input Power(W)6
Speed(rpm)7000
Noise(db)31.5

Product Features

Compact DC Cooling

The AFB0412HHA addresses ventilation needs in industrial control equipment. Delta's brushless DC axial fan format allows cooling airflow to be integrated alongside the equipment's heat-producing assemblies.

The listed 6 W input is relevant to supply sizing and the system energy budget; actual consumption depends on the operating duty. The series combines ball-bearing construction with UL 94V-0 materials, addressing mechanical durability and component flammability requirements. The mounting arrangement and duct transitions should preserve the intended air path so cooling is not lost to leakage or recirculation.

This fan is a practical candidate for equipment builders and service teams when its verified duty point and mounting interface match the finished system.

Application Industry

Frequently Asked Questions

What maximum airflow is listed for AFB0412HHA?

The workbook lists a maximum airflow of 13.855 m3/h. This is not the airflow at every system resistance; use the applicable pressure-flow curve to identify the installed operating point.

Can AFB0412HHA directly replace another fan?

A matching outline alone does not prove compatibility. Check 12VDC, mounting dimensions, connector, pinout, airflow direction, control signals and the required pressure-flow point.

What equipment is AFB0412HHA intended to cool?

AFB0412HHA is listed for Server, Storage and Power Supply cooling. Confirm the installed airflow demand, pressure loss and ambient conditions before approval.

How should the pressure capability of AFB0412HHA be checked?

No maximum-pressure value is present in the filter row. Match the exact-model curve to the system resistance before using the fan in a restricted airflow path.

What power figure is listed for AFB0412HHA?

6 W is shown in the filter data. Check whether the corresponding datasheet defines it as rated, free-air or maximum-load input before sizing the power source.

Is AFB0412HHA suitable for a high-reliability cooling system?

Suitability depends on thermal margin, operating temperature, alarm or feedback requirements and system redundancy. Qualify AFB0412HHA at the actual duty point; the model name alone is not a reliability guarantee.