AFB0624EH is the 6800 rpm choice in the supplied 24VDC, 60 mm axial fan group for server cooling. Its 5.76 W input is higher than the SH and VH entries, a distinction to consider when comparing their thermal designs.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 60*60*25 |
| Max.Air Flow(m³/h) | 65.28 |
| Input Power(W) | 5.76 |
| Speed(rpm) | 6800 |
| Noise(db) | 46.5 |
Designed for power-supply equipment, Delta AFB0624EH brings brushless DC axial fan integration to thermally loaded assemblies. Its role is to move cooling air across components during equipment operation.
The listed 5.76 W input is relevant to supply sizing and the system energy budget; actual consumption depends on the operating duty. The series uses ball-bearing motor support for rotational durability, giving OEMs a service-life-oriented construction for equipment cooling. Good inlet spacing helps reduce turbulence, which matters when balancing usable cooling capacity against installed sound levels.
Choose it for a model-specific cooling requirement, with connector, operating conditions and airflow direction checked before release to production.
Delta AFB0624EH serves server and storage equipment, helping remove heat from processors, drives and other heat-producing assemblies. Airflow supports stable equipment temperatures.
For power-supply equipment, Delta AFB0624EH provides equipment cooling around power-conversion components. Managing electrical conversion losses helps maintain dependable power delivery.
In telecommunications equipment, air movement helps handle continuous communication duty. Delta AFB0624EH supports cooling around densely arranged electronic assemblies, contributing to service continuity.
Delta AFB0624EH supports cooling in industrial control equipment. Air circulation around controllers and electronic modules helps manage heat accumulated within enclosures, supporting stable automation operation.
The provided parameters do not prove a cost saving. Compare purchase price, power at the real operating point, service access, expected life and downtime risk for the complete cooling system.
The listed noise value is 46.5 dB, but compare values only under matching test conditions. Installed noise also depends on speed, restriction, resonance and enclosure geometry.
24VDC is listed for AFB0624EH. Verify the allowable input range, phase, frequency where applicable, polarity and wiring diagram in the exact specification.
The workbook lists a maximum airflow of 65.28 m3/h. This is not the airflow at every system resistance; use the applicable pressure-flow curve to identify the installed operating point.
AFB0624EH is listed for Server and Power Supply cooling. Confirm the installed airflow demand, pressure loss and ambient conditions before approval.

A 1.44 W input makes AFB0624MB a lower-input entry among the listed 24VDC axial fan fans. For server and power-supply ventilation, it provides a 60 x 60 x 15 mm format with a specified 4000 rpm rotor.
Read More
AFB0612HH-A combines a 5000 rpm rotor with a 12VDC axial fan motor for server and power-supply cooling. Its listed 2.04 W input and 74 Pa maximum static pressure accompany a 60 x 60 x 25.4 mm frame.
Read More
AFB1224GHE-C is a 24VDC axial fan for server chassis, with 409.7 m3/h listed maximum airflow. Its 27.6 W input differs from the 12VDC GHE entry; retain the -C suffix when checking connector and control configuration.
Read More
AFB0912HH supports storage-enclosure cooling with a 12VDC axial fan design. At 3200 rpm and 3 W listed input, it represents a distinct operating choice among the supplied 92 mm fans, with a specified 25.4 mm depth.
Read More
Server chassis with space for a 38 mm-deep fan can consider AFB0824SHE, an 80 mm axial model powered by 24VDC. Its listed airflow ceiling is 123.6 m3/h, a useful comparison point for enclosure ventilation designs.
Read More
A deeper 70 x 70 x 38 mm frame distinguishes AFB0712VHE for server and power-supply cooling. The 12VDC axial fan lists 7000 rpm operation and 216.7 Pa maximum pressure, with an 8.4 W input rating.
Read More