Get Quote
Home > Products > By type > Compact Fans > AFB0624VHC | Delta Electronics 24VDC 2.88W Axial Fan for Server and Power Supply Cooling

AFB0624VHC Delta Compact Fan

Brand :
Delta
Model:
AFB0624VHC | Delta Electronics 24VDC 2.88W Axial Fan for Server and Power Supply Cooling
Type:
Compact Fans
Industry:
Data Center Cooling
Description:

AFB0624VHC delivers axial fan airflow from a 24VDC supply for server and power-supply cooling. A listed 47.1 m3/h maximum airflow distinguishes its 60 x 60 x 15 mm format, alongside a 5400 rpm speed rating.

Datasheet:
AFB0624VHC | Delta Electronics 24VDC 2.88W Axial Fan for Server and Power Supply Cooling Datasheet (Pdf)

Product Features

Rated Voltage(V)24
Size(mm)60*60*15
Max.Air Flow(m³/h)47.1
Max.Pressure(Pa)62.9
Input Power(W)2.88
Speed(rpm)5400
Noise(db)38

Product Features

Compact DC Cooling

Equipment manufacturers evaluating telecommunications equipment can consider Delta AFB0624VHC, a brushless DC axial fan. The fan supports heat removal by keeping air moving through the selected cooling path.

A listed speed of 5400 rpm helps define the operating profile when reviewing airflow demand, mechanical mounting and the enclosure's acoustic target. The series combines ball-bearing construction with UL 94V-0 materials, addressing mechanical durability and component flammability requirements. The mounting arrangement and duct transitions should preserve the intended air path so cooling is not lost to leakage or recirculation.

OEM purchasers can specify this model after checking the thermal duty, supply and mechanical fit, keeping reliable equipment operation central to selection.

Application Industry

Frequently Asked Questions

Can AFB0624VHC reduce total ownership cost?

The provided parameters do not prove a cost saving. Compare purchase price, power at the real operating point, service access, expected life and downtime risk for the complete cooling system.

What equipment is AFB0624VHC intended to cool?

AFB0624VHC is listed for Server and Power Supply cooling. Confirm the installed airflow demand, pressure loss and ambient conditions before approval.

How should the pressure capability of AFB0624VHC be checked?

The workbook lists 62.9 Pa maximum pressure. Maximum pressure and maximum airflow occur at different points, so select AFB0624VHC from its curve at the required system resistance.

What should be checked if AFB0624VHC fails to start?

Isolate power first. Verify the approved supply, connector, polarity or phase, control-enable input and any obstruction; follow the exact specification and do not bypass protection circuits.

How should noise from AFB0624VHC be evaluated?

The listed noise value is 38 dB, but compare values only under matching test conditions. Installed noise also depends on speed, restriction, resonance and enclosure geometry.

Is AFB0624VHC suitable for a high-reliability cooling system?

Suitability depends on thermal margin, operating temperature, alarm or feedback requirements and system redundancy. Qualify AFB0624VHC at the actual duty point; the model name alone is not a reliability guarantee.