Home > Products > By type > Compact Fans > AFB0912HD | Delta Electronics 12VDC 1.92W Axial Fan for Server and Power Supply Cooling

AFB0912HD Delta Compact Fan

Brand :
Delta
Model:
AFB0912HD | Delta Electronics 12VDC 1.92W Axial Fan for Server and Power Supply Cooling
Type:
Compact Fans
Industry:
Data Center Cooling
Description:

With a 1.92 W input rating, AFB0912HD offers a modest electrical load for server and power-supply ventilation. This 12VDC axial fan has a 92 x 92 x 20 mm frame and a listed operating speed of 2700 rpm.

Datasheet:
AFB0912HD | Delta Electronics 12VDC 1.92W Axial Fan for Server and Power Supply Cooling Datasheet (Pdf)

Product Features

Rated Voltage(V)12
Size(mm)92*92*20
Max.Air Flow(m³/h)91.8
Max.Pressure(Pa)34.3
Input Power(W)1.92
Speed(rpm)2700
Noise(db)35

Product Features

Quiet Duty Cooling

Equipment manufacturers evaluating telecommunications equipment can consider Delta AFB0912HD, a brushless DC axial fan. The fan supports heat removal by keeping air moving through the selected cooling path.

The 12 V DC supply requirement gives electrical designers a clear basis for matching the fan to the equipment power architecture. The series combines ball-bearing construction with UL 94V-0 materials, addressing mechanical durability and component flammability requirements. A controlled exhaust route limits recirculation, allowing the delivered air to carry heat away rather than return to the inlet.

Equipment manufacturers and maintenance teams should match the complete part number and installation limits for reliable operation across the service cycle.

Application Industry

Frequently Asked Questions

What maximum airflow is listed for AFB0912HD?

The workbook lists a maximum airflow of 91.8 m3/h. This is not the airflow at every system resistance; use the applicable pressure-flow curve to identify the installed operating point.

How should the energy efficiency of AFB0912HD be assessed?

The listed input-power figure is 1.92 W, but efficiency must be evaluated at the required airflow and pressure. Check the applicable fan curve and test conditions before comparison.

What should be checked if AFB0912HD fails to start?

Isolate power first. Verify the approved supply, connector, polarity or phase, control-enable input and any obstruction; follow the exact specification and do not bypass protection circuits.

What installation space is required for AFB0912HD?

The workbook lists 92 x 92 x 20 mm. Confirm overall depth, hole pattern, connector clearance and guard or inlet-ring dimensions in the exact mechanical drawing.

What equipment is AFB0912HD intended to cool?

AFB0912HD is listed for Server and Power Supply cooling. Confirm the installed airflow demand, pressure loss and ambient conditions before approval.