The 2900 rpm AFB1212HHE is a 12VDC axial fan intended for server ventilation. With 5.52 W listed input, it differs from the faster SHE and GHE entries; allow for its 120 mm square frame and 38 mm body depth.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 120*120*38 |
| Max.Air Flow(m³/h) | 204 |
| Max.Pressure(Pa) | 88.3 |
| Input Power(W) | 5.52 |
| Speed(rpm) | 2900 |
| Noise(db) | 44 |
AFB1212HHE is a Delta cooling solution for server and storage equipment. This brushless DC axial fan gives designers a practical means of circulating air through a thermally loaded equipment section.
A listed speed of 2900 rpm helps define the operating profile when reviewing airflow demand, mechanical mounting and the enclosure's acoustic target. The series combines ball-bearing construction with UL 94V-0 materials, addressing mechanical durability and component flammability requirements. Matching the fan curve to the finished air path supports efficient cooling; free-air flow alone does not determine installed performance.
For procurement, retain the complete model code and check the interface against the drawing; this supports repeatable assembly and accurate replacement ordering.
Delta AFB1212HHE serves server and storage equipment, helping remove heat from processors, drives and other heat-producing assemblies. Airflow supports stable equipment temperatures.
For power-supply equipment, Delta AFB1212HHE provides equipment cooling around power-conversion components. Managing electrical conversion losses helps maintain dependable power delivery.
In telecommunications equipment, air movement helps handle continuous communication duty. Delta AFB1212HHE supports cooling around densely arranged electronic assemblies, contributing to service continuity.
Delta AFB1212HHE supports cooling in industrial control equipment. Air circulation around controllers and electronic modules helps manage heat accumulated within enclosures, supporting stable automation operation.
AFB1212HHE provides a defined axial fan format with a listed 2900 rpm speed in a 120 x 120 x 38 mm size. Compare its fan curve with the actual duty point rather than assuming a universal advantage.
The workbook lists 120 x 120 x 38 mm. Confirm overall depth, hole pattern, connector clearance and guard or inlet-ring dimensions in the exact mechanical drawing.
The supplied filter data does not establish an unconditional 24/7 rating. Confirm bearing life, temperature range, duty cycle and derating in the exact datasheet, then validate system-level redundancy.
The workbook lists 88.3 Pa maximum pressure. Maximum pressure and maximum airflow occur at different points, so select AFB1212HHE from its curve at the required system resistance.
AFB1212HHE is listed for Server and Power Supply cooling. Confirm the installed airflow demand, pressure loss and ambient conditions before approval.

A listed 3500 rpm speed and 6.48 W input identify AFB1224HHE for server and power-supply cooling. This 24VDC axial fan has a 120 x 120 x 38 mm frame, providing a specific fit for 38 mm-deep installations.
Read More
A 1.44 W input makes AFB0624MB a lower-input entry among the listed 24VDC axial fan fans. For server and power-supply ventilation, it provides a 60 x 60 x 15 mm format with a specified 4000 rpm rotor.
Read More
AFB0612HH-A combines a 5000 rpm rotor with a 12VDC axial fan motor for server and power-supply cooling. Its listed 2.04 W input and 74 Pa maximum static pressure accompany a 60 x 60 x 25.4 mm frame.
Read More
AFB1224GHE-C is a 24VDC axial fan for server chassis, with 409.7 m3/h listed maximum airflow. Its 27.6 W input differs from the 12VDC GHE entry; retain the -C suffix when checking connector and control configuration.
Read More
AFB0912HH supports storage-enclosure cooling with a 12VDC axial fan design. At 3200 rpm and 3 W listed input, it represents a distinct operating choice among the supplied 92 mm fans, with a specified 25.4 mm depth.
Read More
Server chassis with space for a 38 mm-deep fan can consider AFB0824SHE, an 80 mm axial model powered by 24VDC. Its listed airflow ceiling is 123.6 m3/h, a useful comparison point for enclosure ventilation designs.
Read More