FFB1212EHE supports server and telecom ventilation with 322.8 m3/h listed maximum airflow. The 12VDC axial fan combines a 120 x 120 x 38 mm frame with a 4000 rpm speed and 24 W electrical input.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 120×120×38 |
| Max.Air Flow(m³/h) | 322.8 |
| Max.Pressure(Pa) | 174.4 |
| Input Power(W) | 24 |
| Speed(rpm) | 4000 |
| Noise(db) | 59 |
The Delta FFB1212EHE is a brushless DC axial fan for server and storage equipment. It provides a defined airflow path where equipment layout leaves limited room for passive heat removal.
The listed 24 W input is relevant to supply sizing and the system energy budget; actual consumption depends on the operating duty. Its high-performance fan family emphasizes air delivery and pressure capability, helping address the resistance of densely populated equipment. Matching the fan curve to the finished air path supports efficient cooling; free-air flow alone does not determine installed performance.
For system integrators, a confirmed operating point and exact interface match provide the basis for stable cooling and dependable replacement planning.
Delta FFB1212EHE serves server and storage equipment, helping remove heat from processors, drives and other heat-producing assemblies. Airflow supports stable equipment temperatures.
Delta FFB1212EHE supports cooling in uninterruptible power systems. Air circulation around power electronics helps manage heat produced during power conversion, supporting stable backup-power operation.
In power-supply equipment, Delta FFB1212EHE helps remove heat from power-conversion components. The cooling solution addresses electrical conversion losses to support dependable power delivery.
For telecommunications equipment, Delta FFB1212EHE provides equipment cooling around densely arranged electronic assemblies. Managing continuous communication duty helps maintain service continuity.
Isolate power first. Verify the approved supply, connector, polarity or phase, control-enable input and any obstruction; follow the exact specification and do not bypass protection circuits.
FFB1212EHE is listed for Server and Telecommunications cooling. Confirm the installed airflow demand, pressure loss and ambient conditions before approval.
Allow for the listed 120 x 120 x 38 mm size and follow the exact mounting drawing. Keep inlet and outlet clear, use the specified fasteners and verify wiring before energizing the fan.
RoHS Compliant is listed in the workbook. Obtain the current exact-model declaration and datasheet before claiming safety approvals, ingress protection or international compliance.
The workbook lists a maximum airflow of 322.8 m3/h. This is not the airflow at every system resistance; use the applicable pressure-flow curve to identify the installed operating point.
The listed noise value is 59 dB, but compare values only under matching test conditions. Installed noise also depends on speed, restriction, resonance and enclosure geometry.

For server and telecom ventilation, FFB1224EHE is a 24VDC axial fan with a 24 W input rating. Its 120 x 120 x 38 mm dimensions and 4000 rpm speed offer a defined mechanical and electrical selection profile.
Read More
FFB0924EHE combines a 92 x 92 x 38 mm axial fan assembly with 24VDC operation for telecom and server cooling. Its listed 187 m3/h maximum airflow is paired with a 4800 rpm speed and 12 W input.
Read More
FFB0612EHE is the 12VDC axial fan configuration with 14.4 W listed input in this 60 mm telecom-cooling group. The 38 mm-deep housing permits a specific mechanical fit; its nominal speed is recorded as 8000 rpm.
Read More
The FFB0824EHE is an 80 mm axial fan for telecom cooling on 24VDC. With 5700 rpm listed for its 38 mm-deep assembly, rotor speed and housing depth are central checks when choosing this model for an equipment rack.
Read More
For server airflow in an 80 mm frame, FFB0812EHE uses a 38 mm-deep axial design. The 12VDC fan has a 5700 rpm rating and a listed maximum airflow of 136 m3/h, with 10.8 W input power specified.
Read More
FFB0624EHE brings a 38 mm-deep, 60 mm axial format to server and telecom cooling. The 24VDC model runs at 8000 rpm, with 85.34 m3/h maximum airflow specified for this higher-speed enclosure fan.
Read More