GTW012FU804-U00 brings EC axial operation to a 120 x 120 x 38 mm server-cooling format. With 220VAC listed in the supplied table, the fan is specified at 4200 rpm and 246.5 m3/h maximum airflow.
| Rated Voltage(V) | 220 |
|---|---|
| Size(mm) | 120*120*38 |
| Max.Air Flow(m³/h) | 246.5 |
| Max.Pressure(Pa) | 112.1 |
| Input Power(W) | 11 |
| Speed(rpm) | 4200 |
| Noise(db) | 54.9 |
Delta GTW012FU804-U00 serves precision cooling equipment as an EC axial fan. Equipment builders can use its mechanical format to establish forced ventilation near heat-producing parts.
The listed 11 W power rating is relevant to supply sizing and the system energy budget; actual consumption depends on the operating duty. Electronic commutation is part of the EC motor architecture; speed-control inputs must be checked against the complete electrical specification. The mounting arrangement and duct transitions should preserve the intended air path so cooling is not lost to leakage or recirculation.
OEM purchasers can specify this model after checking the thermal duty, supply and mechanical fit, keeping reliable equipment operation central to selection.
In precision cooling equipment, Delta GTW012FU804-U00 helps remove heat from heat-exchange sections. The cooling solution addresses continuous temperature-control demand to support stable environmental conditions.
Delta GTW012FU804-U00 serves server and storage equipment, helping remove heat from processors, drives and other heat-producing assemblies. Airflow supports stable equipment temperatures.
In telecommunications equipment, air movement helps handle continuous communication duty. Delta GTW012FU804-U00 supports cooling around densely arranged electronic assemblies, contributing to service continuity.
4200 rpm is listed in the workbook. This value alone does not establish adjustable-speed capability; confirm the control input and permitted operating range in the exact datasheet.
A matching outline alone does not prove compatibility. Check 220VAC, mounting dimensions, connector, pinout, airflow direction, control signals and the required pressure-flow point.
Suitability depends on thermal margin, operating temperature, alarm or feedback requirements and system redundancy. Qualify GTW012FU804-U00 at the actual duty point; the model name alone is not a reliability guarantee.
The workbook lists a maximum airflow of 246.5 m3/h. This is not the airflow at every system resistance; use the applicable pressure-flow curve to identify the installed operating point.
GTW012FU804-U00 is listed for Server and Precision cooling. Confirm the installed airflow demand, pressure loss and ambient conditions before approval.

GTW091PUR22EA offers EC axial fan ventilation for server cooling on three-phase 380-480VAC. A listed 910 mm size and 950 rpm speed distinguish this entry, with 30984 m3/h maximum airflow in the supplied table.
Read More
GTW080PUU23E is an EC axial fan listed for three-phase 380-480VAC server cooling. Its test table records 19626 m3/h at 265 Pa and 1200 rpm without a guard, providing a loaded operating point for system comparison.
Read More
GTW050EUD19E is listed as an EC axial fan for server and precision cooling on single-phase 200-277VAC. The supplied 497 mm size and 1500 rpm speed accompany a maximum airflow specification of 9046 m3/h.
Read More
The GTW091PUU23E is an EC axial fan for server and precision cooling, listed for three-phase 380-480VAC. Its PDF records 36185.9 m3/h at free air and 1100 rpm without a fan guard, identifying the test condition.
Read More
GTW091PUR22E pairs nominal 400VAC EC axial operation with a 950 rpm speed for server and precision cooling. Its PDF lists 30984 m3/h maximum airflow and 0-10V/PWM control for adjusting the fan speed.
Read More
An 800 mm EC axial fan format identifies GTW080PUR23E for server and precision cooling. Listed for three-phase 380-480VAC, the model has a 2200 W input specification; exact control interfaces need confirmation.
Read More